GrowerSELECT® Installation Manuals Binder

Hog Slat Inc. Newton Grove, NC USA May 2014 2 Grow-Flex TM Feed System HS598 DELAY TIMER KIT ASSEMBLY REF # PART # DESCRIPTION 1 HS599-1 ENCLOSURE ,PLASTIC 2 HS599-2 COVER, PLASTIC 3 60932 Screw 10-24 X 3/4" 4 HS599-3 GASKET 5 HS599-5 COMPONENT MOUNT 6 EL1088 TIME DELAY 1-100 sec, 7 EL1008 RELAY, 240VAC COIL, DPST 25 AMP 8 61646 LIQUID TIGHT CONNECTOR NYLON 1/2'' 9 HSPT-003 16/4 CORD ASSEMBLY Installation: 1. Delay Relay Kit should be installed in a convenient location near the feed system “Power Drive Control Unit” or other equipment being connected. 2. Initial delay set-point should be set to approximately 15 seconds. 3. Further adjustment to the delay time may be necessary depending upon fill system set-up. Safety Decal HSLABEL-008

RkJQdWJsaXNoZXIy MTA3MzU=