GrowerSELECT® Installation Manuals Binder

Hog Slat Inc. Newton Grove, NC USA August 2016 30 Evaporative Cooling System 4. Finally, place the tank cap (HSES-41) onto the tank. A section of the cap will have to be removed. An example is shown below in Figure 36.  EXACT DIMENSION OF CUT SHOULD BE DETERMINED BY INSTALLER AS FEED PIPE AND SIZE MAY VARY Figure 36 Pump Wiring Instruction Wire Connection: Again, make sure that power is disconnected from system prior to servicing . This Power Unit is supplied prewired for 230 volt operation with the proper rotation direction for correct motor rotation. If 115 volt operation is required, please see wiring instruction on Motor Data Label for converting to 115 volt operation. Black wire should be connected to L1(M1) and White wire should connect to L2(M2). Green should be connected to Ground (See Figure 37) Figure 37 WARNING ELECTRICAL SHOCK HAZARD!  Motor replacement and the associated wiring changes should only be made by qualified and properly trained individuals.  Failure to follow the above warning can cause improper equipment function, premature failure of equipment or electrical shock, leading to property damage or personal injury.