GrowerSELECT® Installation Manuals Binder

Hog Slat Inc. Newton Grove, NC USA August 2016 8 Ventilation Systems 4. DO NOT OPERATE MACHINE while hanging on this bolt. Level machine and secure machine using 3/8” x 2” Lag bolts (supplied) in the (6) mounting locations. (Figure 2) Figure 2 5. When connecting chains, the load nut should be near the “Closed” position to allow enough chain/cable for manual winch connection. 6. Run chain ends through side of machine around sprocket down to the load block. Route chains around sprockets as shown in below figures that best suits the application. (4) Inside chassis mounting locations (2) External Mounting Locations If mounting does not allow the use of these locations, install 3/8“ to 1/2” diameter bolts with nuts in the holes to secure internal thrust plate to machine cabinet. Failure to secure the thrust plate could result in plate damage during heavy-load conditions.

RkJQdWJsaXNoZXIy MTA3MzU=