GrowerSELECT® Installation Manuals Binder

Hog Slat Inc. Newton Grove, NC USA August 2016 19 Ventilation Systems OPERATION Figure 23 “ Operation Mode” Switch Up – Manual Mode Center - OFF Down - Auto Mode “Manual Override” Switch (only functions if “Operation Mode” switch is in “Manual Mode”) Up - “Open” operation Center - OFF Down - “Close” operation To operate machine in Auto mode for vent control: set “Operation Mode” to “Auto”. In this position the machine will be controlled by the ventilation controller. To operate in Manual mode: Set “Operation Mode” switch to “MAN”. “Manual Over-ride” switch now may be used to manually operate

RkJQdWJsaXNoZXIy MTA3MzU=