2024 Hog Slat/Georgia Poultry Retail Product Catalog

211 COOL CELL In order to ensure maximum pad life for pads in excess of 5 feet in heigh is recommended to install pad retainers to maintain pad straightness. See documentation below form HSMANUAL-019 (Evap System Manual) Pad Retainer Installati Pad retainers (HS756) Are recommend for any pads exceeding 5 feet in height. Pad retainers are sold individually (HS756) or in boxes of 20 (HS756-BX20 Pad retainers may be used on any height of pad. Pad retainers add additional rigidity to the center of pads to help maintain straightness over time. To install pad retainers run 1”x4” lumber for length of system. Pad retaine should be installed to support pads at their midpoint. See Figure Below. In order to ensure maximum pad life for pads in excess of 5 feet in heigh is recommended to install pad retainers to maintain pad straightness. See documentation below form HSMANUAL-019 (Evap System Manual) Pad Retainer Installati Pad retainers (HS756) Are recommend for any pads exceeding 5 feet in height. Pad retainers are sold individually (HS756) or in boxes of 20 (HS756-BX20 Pad retainers may be used on any height of pad. Pad retainers add additional rigidity to the center of pads to help maintain straightness over time. To install pad retainers run 1”x4” lumber for length of system. Pad retaine should be installed to support pads at their midpoint. See Figure Below. INSTALL AT MIDPOINT #J-TFV....................................................................fits #610802, Trough-O-Matic The unique patented design of the Hudson Cattle float uses fluid pressure, as opposed to a lever arm and ball, as the force to close the valve. This compact, self-contained design greatly enhances the valve’s reliability. The valve body is made of durable glass-filled nylon. 1” Cattle Float #60390..............................................................................................1” Cattle Float #60390B03..................................................................Bracket for Hudson valve Kit complete with Cone Screen, Retainer Ring, Diaphragm and Float. Repair Kit for Cattle Float #603900......................................................................Repair Kit for Cattle Float Cool Cell Clean-Out Brush #H6650-5400...............................................................................Cleaning brush Strainers & Screens #11271-VI..............................................................................1-1/2” In-Line Strainer #10866-VI.................................................20 Mesh Screen for In-Line Strainer Trough-O-Matic Float Valve #610802................................................................................Polystyrene Housing #FP0572...................................................................................Aluminum Housing • for Megacool and other cool cell systems Topaz Float Valve by Jobe #JOMFV1D...............................MegaFlow High Flow 1” Inlet 80 GPM @ 65 PSI #JOMFV20DLT..................MegaFlow High Flow 3/4” inlet 65 GPM @ 65 PSI #JORJV20HF..............................Rojo Low Flow 3/4” Inlet 6.8 GPM @ 75 PSI #JOTPV1D........................................Topaz High Flow 1” Inlet 80 GPM @ 75 PSI #JOTPV20DLT..........................Topaz High Flow 3/4” Inlet 55 GPM @ 75 PSI • PT75LS 3/4” In/Out Kerick Float Valve Tank Mount #HS826.............................................................................Valve Float Tank Mount Kerick Valve Repair Parts #KPT75SS.................................................................Valve only 3/4” inlet/Outlet #KPF06..............................................................................................6” round float #HSES-RA11..................................................................................SS eye bolt assy #KPF444-BK..................................................................................4” square float Converts float valves to a high flow Diaphragm style valve. Increased flow rate fills tanks faster during periods of peak demand. Fits most clamp-on floats and installs quickly without drilling. Contains an internal filter and comes with a manufacture 2 year warranty. Boost flow rates over 4 times that of using the Trough O Matic alone depending on your hose flow rate. Tranz Former Valve #JOTPV20DLT #JOMFV1D Brush attachment for cleaning water distribution pipes.Manufactured with a female slip coupling that glues directly to 3/4” PVC pipe creating a long handle capable of reaching the entire length of the system. A) #527458..................................................................1-1/2” In-line check valve B) #603841 ������������������������������������������������������������������������������������������1-1/2” Union PVC Fittings Internal parts are of ABS plastic, silicone, and stainless steel. When properly installed, the valve will meet anti-siphon requirements. 300 gph at 30 psi. Bracket sold separately. Flow rate: 245 gallons/hour Dimensions: 3” W x 7.5” L x 3.5” High Operating pressure: 20-50 PSI #KPF444-BK #KPT75SS #KPF06 Stainless steel wire retainers used to hold cool cell pads in place. Pad retainers add additional rigidity to the center of pads to help maintain straightness over time. Retainer Clips should be used to stabilize pads that are more than five feet high and and when pads are stacked. PAD RETAINER CLIP #HS756...............................................................................Cool Cell Retainer Clip A) B)

RkJQdWJsaXNoZXIy MTA3MzU=