Hog Slat - Swine Ventilation Systems Information Flyer

15 WWW.HOGSLAT.COM 100% Virgin Kraft Paper Offers a structurally sound paper with great absorbency for maximum cooling efficiency. 2 Foot Width Offered exclusively in 2 foot widths providing a strong pad, while reducing the number of pad seams. 3/4” ProTec Edging Reinforces the pad face to prevent against damage from UV light, severe outdoor weather and mechanical cleaning processes. ProTec edging also prevents algae and mineral deposit build-up to help increase pad life. Built for the Extreme Cooling animals in the deep summer means battling extreme conditions. You need a replacement pad that can handle the extremes. H2-XCELL pad delivers. Maintenance Although the H2-XCELL pads have been designed for the harshest of conditions and the most demanding applications proper maintence is still required to achieve maximum life of the evaportaive pads. This includes but is not limited to allowing the pads to completely dry out once per 24 hour period, routine flushing of the system, and ensuring pads are not resting in standing water. 2’ *Performance date shown above is results from Bess Test 24290 Airflow fpm Cooling Efficiency 100 88.10 300 87.50 500 78.57 700 67.54 * The pads are soaked for 1 hour before testing. A 4 ft. x 4 ft. section of the cool cell is tested, and water flow is maintained at 3.5 gallons per minute during the test. Efficiency is calculated using humidity, inlet temperature, and outlet temperature. 0.00 0.05 0.10 0.15 0.20 0.25 0 100 200 300 400 500 600 700 800 Pressure (in H2O) Velocity (cfm) H2XCell Evaporative Media Pressure Drop Chart H2XCELL Pressure Drop Velocity (Ft./Min.) PART # DIMENSIONS H2X-6224E 6” D x24” W x 24” H H2X-6324E 6” D x24” W x 36” H H2X-6424E 6” D x24” W x 48” H H2X-6524E 6” D x24” W x 60” H H2X-6624E 6” D x24” W x 72” H H2X-6724E 6” D x24” W x 84” H H2X-Cell Cool Cell Pad with Pro Tec Edge Standard H2Xcell pads are offered with Exterior edge guard. 2” Bottom Edge Guard No Edge Guard 0 200 300 400 500 600 700 800 Velocity (cfm) H2XCell Evaporative Media Pressure Drop Chart H2XCELL Airflow fpm cooling efficiency 100 88.10 300 87.50 500 78.57 700 67.54 pads are soaked for 1 hours before testing. 4ftx4ft section of cool cell tested. Water flow is maintained at 3.5 gallon per minute during test. Efficiency is calculated using humidity, inlet, and outlet temperature. 0.00 10.00 20.00 30.00 40.00 50.00 60.00 70.00 80.00 90.00 100.00 0 100 200 300 400 500 600 700 800 Efficiency (%) Airflow (feet/min) H2XCELL Efficiency Efficiency (%) Cooling Efficiency Airflow (Ft./Min.) Airflow fpm cooling efficiency 100 88.10 300 87.50 500 78.57 700 67.54 pads are soaked for 1 hours before testing. 4ftx4ft section of cool cell tested. Water flow is maintained at 3.5 gallon per minute during test. Efficiency is calculated using humidity, inlet, and outlet temperature. 0.00 10.00 20.00 30.00 40.00 50.00 60.00 70.00 80.00 90.00 100.00 0 100 200 300 400 500 600 700 800 Efficiency (%) Airflow (feet/min) H2XCELL Efficiency Effiency Pressure (in H20)

RkJQdWJsaXNoZXIy MTA3MzU=