GrowerSELECT AS-51X Series Airstorm Fiberglass Fan Installation Manual

Hog Slat Inc. Newton Grove, NC USA August 2022 Air Storm Fans AS-51XEBDLP Fan 51" FBG 1.5HP 1725RPM 115/230V 60HZ Only No Cone AS-51XEBDLP3 Fan 51" FBG 1.5HP 1725RPM 230/430V 3P 60HZ Only No Cone AS-51XEBDLP-V Fan 51" FBG 1.5HP 1725RPM 230/430 VFD 1/3P Drive Inc No Cone ASC-51XEBDLP Fan 51" FBG 1.5HP 1725RPM 115/230V 60HZ Only No Cone ASC-51XEBDLP3 Fan 51" FBG 1.5HP 1725RPM 230/430V 3P 60HZ Only No Cone ASC-51XEBDLP-V Fan 51" FBG 1.5HP 1725RPM 230/430 VFD 1/3P Drive Inc No Cone (Includes French Version - Comprend la version française) (Includes Spanish Version - Incluye versión en español)

Hog Slat Inc. Newton Grove, NC August 2022 2 Air Storm Fans Table of Contents GrowerSELECT General Page........................................................................................................................... 4 Safety ................................................................................................................................................................. 5 Warning Labels ................................................................................................................................................ 5 Installation........................................................................................................................................................ 6 Operation Safety .............................................................................................................................................. 6 Maintenance Safety.......................................................................................................................................... 6 Installation ......................................................................................................................................................... 6 Framing............................................................................................................................................................ 6 Assembly ......................................................................................................................................................... 8 Wiring............................................................................................................................................................... 13 VFD Initial Set Up. ............................................................................................................................................ 17 Pre-Operation Assessment............................................................................................................................. 20 Operation ......................................................................................................................................................... 20 Maintenance..................................................................................................................................................... 21 Troubleshooting .............................................................................................................................................. 23 Performance..................................................................................................................................................... 24 FREQUENCY DRIVE CURVES......................................................................................................................... 25 Exploded Diagrams/Replacement Parts ......................................................................................................... 26 Hog Slat Limited Warranty .............................................................................................................................. 27 Page générale de GrowerSELECT ...................................................................................................................... 30 Sécurité ............................................................................................................................................................. 31 Étiquettes d’avertissement ............................................................................................................................. 31 Installation .................................................................................................................................................... 32 Sécurité de fonctionnement ............................................................................................................................ 32 Sécurité d’entretien ........................................................................................................................................ 32 Installation ....................................................................................................................................................... 32 Ossature ........................................................................................................................................................ 32 Assemblage .................................................................................................................................................... 34 Câblage ............................................................................................................................................................. 39 Configuration initiale. ....................................................................................................................................... 43 Évaluation de préfonctionnement .................................................................................................................. 46 Fonctionnement................................................................................................................................................ 46 Entretien ........................................................................................................................................................... 47 Dépannage ........................................................................................................................................................ 49

Hog Slat Inc. Newton Grove, NC August 2022 3 Air Storm Fans Rendement ....................................................................................................................................................... 50 COURBES DE VARIATEUR DE FRÉQUENCE................................................................................................. 51 Schémas éclatés/Pièces de rechange ................................................................................................................ 52 Garantie limitée Hog Slat .................................................................................................................................. 53 Página general de GrowerSELECT ..................................................................................................................... 56 Seguridad .......................................................................................................................................................... 57 Etiquetas de advertencia ................................................................................................................................ 57 Instalación ..................................................................................................................................................... 58 Seguridad en el funcionamiento .................................................................................................................... 58 Seguridad en el mantenimiento ..................................................................................................................... 58 Instalación ........................................................................................................................................................ 58 Enmarcado .................................................................................................................................................... 58 Montaje.......................................................................................................................................................... 60 Alambrado ........................................................................................................................................................ 65 Configuración Inicial VFD. ................................................................................................................................ 69 Evaluación previa a la operación ................................................................................................................... 72 Rendimiento ..................................................................................................................................................... 76 CURVAS DE IMPULSOR DE FRECUENCIA............................................................................................................ 77 Diagramas de despiece /Piezas de reemplazo .................................................................................................. 78 Garantía limitada de Hog Slat.......................................................................................................................... 79

Hog Slat Inc. Newton Grove, NC August 2022 4 Air Storm Fans GrowerSELECT General Page General Installation Notes: Make sure that power is disconnected from system prior to servicing. Installation of this equipment and related OEM equipment should be in accordance with these instructions, OEM’s installation instructions and local codes (if applicable). Failure to follow specified instructions may cause damage to equipment and/or personal injury or death. Take special note of any Warnings or Safety Decals on the equipment and in manuals. Always wear protective clothing and any applicable Personal Protective Equipment (Safety Glasses and/or Ear Plugs) when working with the equipment. Discarded materials, equipment and boxes should be recycled in accordance with local and national codes. Safety Instructions: Read all safety messages in this manual and on equipment safety decals. Follow recommended precautions and safe operating practices. Ground all electrical equipment for safety. Ground all non-current carrying metal parts to guard against electrical shock. Always keep safety decals in good condition and replace missing or damaged decals.

Hog Slat Inc. Newton Grove, NC August 2022 5 Air Storm Fans Safety Warning Labels Warning Decals have been placed on the equipment to warn of potentially dangerous situations. Care should be taken to keep this information intact and easy to read at all times. Replace missing or damaged safety signs. Safety–Alert Symbol This is a safety–alert symbol. When you see this symbol on your equipment, be alert to the potential for personal injury. GrowerSelect equipment is designed to be installed and operated as safely as possible...however, hazards do exist. Safety decals should be read and understood thoroughly by individuals within the local area of the fan. Safety decals should be visible from both the front and back of the fan. Should a decal be missing or damaged, please contact Hog Slat Inc. for a free replacement: Hog Slat Inc. 206 Fayetteville St. Newton Grove, NC 28366 Toll Free: 800-949-4647 Local: 910-594-0219 The below safety decal should be represented and visible on both the front and back sides of the fan. This label is identified by the HSLABEL-080 part number in the lower right corner. WARNING – FLYING OBJECTS AND ROTATING PARTS Ensure fan guards are in place during operation. Securely tighten propeller to shaft to avoid slipping. Disconnect power supply for inspection or service when guards are removed and personnel are exposed to propeller. WARNING – HIGH VOLTAGE Disconnect electrical power before inspecting or servicing equipment unless maintenance instructions specifically states otherwise. Ground all electrical equipment for safety. All electrical wiring must be done by a qualified electrician in accordance with local and national electrical codes. Ground all non-current carrying metal parts to guard against electrical shock. With the exception of motor overload protection, electrical disconnects and over current protection are not supplied with the equipment.

Hog Slat Inc. Newton Grove, NC August 2022 6 Air Storm Fans Installation Prior to any installation product should be inspected for any damage caused during shipping. Any damage found should be documented and communicated to liable parties. Operation Safety When fan is in operation no attempt should be made to service or interact with parts from the fan. Any attempt to interact with fan parts while the fan is operating could result in injury. Inlet and exit guards and or shutters are in place to help prevent foreign objects from entering inside the outer perimeter of the housing. If maintenance to the fan is required, interrupt the source of power to the motor and allow propeller to come to a complete stop before moving forward with any efforts to service. Maintenance Safety Air Storm Fans are designed and built with operator safety in mind. Some safeguards must be disassembled or removed for the parts to be serviced or replaced. As this fan does have moving parts and is supplied with electrical power, steps must be taken to ensure safety around these presented hazards. READ THESE INSTRUCTIONS BEFORE SERVICE OR PART REPLACEMENT 1. Read and understand the operating manual before trying to install or operate Air Storm Fans. 2. Power supply should be turned OFF and LOCKED OUT for service to motor and electrical components. Use CAUTION in checking voltage or other procedures requiring power to be ON. 3. DO NOT attempt to bypass any safety features or devices to operate the fan. 4. Keep fan clean of all debris that may collect the motor, prop, and any bearings, belts, or pulleys. 5. Use CAUTION is working around all moving parts of the fan. Fan guards or shutters must be in place before fan can be safely started and operational. Installation Framing The rough in opening for the fan is an exact measurement that accounts for the heads of fasteners and openings for fan. Ensure there is proper clearance for installation or rough opening may require larger measurements. Fan Model Rough Opening (Width x Height) 51” Fiberglass Exhaust Fan 55” X 55” (139.7 cm x 139.7 cm) See Diagram on Next page for Wall Thickness Specific Dimensions

Hog Slat Inc. Newton Grove, NC August 2022 7 Air Storm Fans ! In some applications the slope on the fan housing requires exterior finish material to extend 3/4" below the top of the rough opening!

Hog Slat Inc. Newton Grove, NC August 2022 8 Air Storm Fans Assembly 1. Remove packaging from Fan and cone if applicable.  Locate hardware kit(s) and supplied literature and store for later use.  Ensure not to damage the fan or components during this step. 2. Remove shutter from fan housing then from the inside of the building insert fan shroud into rough opening. 3. Using supplied #14 Sheet Metal Screws (805060), secure housing to framework.  A total of 8 fasteners are recommended to completely secure fan. Each corner should be secured along with the midpoint between each corner.  Ensure adequate room is allowed to the inside of the fasteners for the shutter to mount flush to the fan housing.

Hog Slat Inc. Newton Grove, NC August 2022 9 Air Storm Fans One Piece Cone Mounting OPTION 1 4 Insert cone onto fan housing orifice.  Align predrilled holes in cone with cone support brackets and secure with supplied 5/16”x 1” stainless bolts, washers, and lock nuts.  Slotted holes are provided in the cone for easier installation.

Hog Slat Inc. Newton Grove, NC August 2022 10 Air Storm Fans OPTION 2 4. Insert cone onto fan housing orifice.  Align predrilled holes in cone with predrilled holes in housing and secure.  Slotted holes are provided in the cone for easier installation.  Assemble as shown below with the flat head bolts, lock nuts, and fender washers.  ! FLAT HEAD BOLTS SHOULD BE INSTALLED FLUSH IN HOUSING WITH LOCK NUTS AND WASHER ON THE EXTERIOR OF THE CONE!

Hog Slat Inc. Newton Grove, NC August 2022 11 Air Storm Fans 5 Place the fan exit guard onto the outlet flange of the cone as shown below.  Secure with supplied fasteners with the bolt head facing the building and flange nuts facing away from fan. 6 Using a 1/2” drill bit, drill a relief hole in the housing at desired location for entry of power cord.  ! ENSURE HOLE LOCATION WILL NOT ALLOW POWER CORD TO APPROACH THE PATH OF THE ROTATING FAN BLADE OR SHUTTER ACTION!  Also ensure hole location will not allow excessive entry of water during adverse weather conditions  Image shown is recommendation only! Actual point of power entry should be determined by installer. 7 A second relief hole is recommended in most applications in the bottom of the housing to allow drainage of any liquid that could accumulate in the bottom of the housing. This hole should be drilled in base of the housing centered between the vertical support and orifice exit.

Hog Slat Inc. Newton Grove, NC August 2022 12 Air Storm Fans 8 From the interior of the house, use WS-001 Hardware package contents to secure the shutter to the fan inlet opening. Place shutter into fan inlet opening. Ensure shutter is oriented so shutter will swing upward when air flows from the interior of the house through the fan to the exterior of the house. PRE DRILLED HOLES ARE PROVIDED IN THE HOUSING FOR THE BOTTOM 2 RETAINER CLIPS TO ENSURE SHUTTER IS CENTERED. EACH PRE DRILLED HOLE IS ACCOMPANIED BY A DECAL NOTING HOLE DESIGN FUNCTION. 9 Attach (8) shutter retainer clips with aluminum washer and self-tapping screw to fan housing. Space the retainer clips evenly between securing screws applied in step 2. THIS COMPLETES THE HOUSING ASSEMBLY OF THE FAN

Hog Slat Inc. Newton Grove, NC August 2022 13 Air Storm Fans Wiring To access motor, turn shutter retainer clips so shutter can be removed. Again, make sure that power is disconnected from system prior to servicing. Always ensure proper prop rotation after install or motor replacement. During operation air should be directed from inside the building to the outside. ALWAYS FOLLOW MOTOR WIRING DIAGRAM PROVIDED ON MOTOR! ELECTRICAL SHOCK HAZARD!  Motor replacement and the associated wiring changes should only be made by qualified and properly trained individuals.  Failure to follow the above warning can cause improper equipment function, premature failure of equipment or electrical shock, leading to property damage or personal injury. Single Phase (230 Volt Wiring) Three Phase (230/460 Wiring) -note rotation, if change is needed swap any leg (L1, L2, or L3).

Hog Slat Inc. Newton Grove, NC August 2022 14 Air Storm Fans If you have purchased a product with a VFD Motor please see below! The following motors DO NOT contain internal thermal protection. They are intended to be used in conjunction with a variable frequency drive (Listed in table below). If any of the motors listed below are used in an application where they are not directly controlled by a variable frequency drive, then INSTALLATION/VALIDATION OF EXTERNAL THERMAL PROTECTION IS REQUIRED! EXTERNAL THERMAL PROTECTION SHOULD BE SIZED APPROPRIATELY Please reference NEC 430.31/430.32/430.40 for additional information regarding overload protection sizing. Motor Drive HS9308-VFD HSFI-1001 HS9306A-VFD HSFI-1001 HS9309-VFD HSFI-1001 HS9314-VFD HSFI-1002 HS9378-VFD HSFI-1002 NOTE: Please be aware that when determining wire and or breaker size and layout that fans with phase conversions (Single to Three Phase) should be sized according to the AMP draw of Drive and not the motor. Examples are shown below. Wire size should be appropriate to accommodate Drive’s input rated Amperage. The product is intended to be installed in accordance with all local and national codes. Fan Model Number input Rated Amps AS-14EDDLP-V 8.8A AS-18EDDLP-V 8.8A AS-24EDDLP-V 8.8A AS-36EDDLPA-V 8.8A AS-54XEBDLP-V 13.3A AS-57EBDBP-V 13.3A AS-57EBDBPG-V 13.3A AS-54EDDLP-ID 20.0A WS-F52B2A-V 13.3A WS-54SBDLA-V 13.3A WS-54PBDBG-V 13.3A

Hog Slat Inc. Newton Grove, NC August 2022 15 Air Storm Fans

Hog Slat Inc. Newton Grove, NC August 2022 16 Air Storm Fans

Hog Slat Inc. Newton Grove, NC August 2022 17 Air Storm Fans VFD Initial Set Up. The following settings should be input to the drive initially. The start source, standard reference, and minimum frequency setting should be adjusted following minimum ventilation testing. In order to adjust the settings, provide power to the drive and depress the blue M button to access the set point menu. Example is provided below. To access/change settings depress blue M button, using the up and down arrows scroll until desired setting is on the display screen, Depress the blue M button to select the setting, using the up and down arrow keys input desired value. Once desired value is displayed depress the blue M butting again to save the setting. Use up and down arrows to advance to next setting. Setting 60Hz (208-240V) Supply 50Hz (208-240V) Supply P100 Start Control Source 0 0 P101 Standard Reference Source 0 0 P102 Minimum Frequency 30 30 P103 Maximum Frequency 60 50 P104 Acceleration Time 7 7 P105 Deceleration Time 7 7 P110 Start Method 5 5 P152 Scaling Frequency 60 50 P161 Speed at Max Frequency 60 50 P302 Motor Rated Voltage 230 220 P303 Motor Rated Current FLA from Motor @230V 60HZ FLA from Motor @ 220V 50Hz P304 Motor Rated Frequency 60 50 P305 Motor Rated Speed RPM from Motor @60Hz RPM from Motor @ 50Hz TO RESET DRIVE TO FACTORY SETTINGS CHANGE SETTING P199 TO 03 (For 60 Hz) OR 04 (For 50 Hz)

Hog Slat Inc. Newton Grove, NC August 2022 18 Air Storm Fans Minimum Ventilation Testing The following steps should be taken BEFORE ANIAMALS ARE PLACED! If two drives are present both drives must be set up and tested simultaneously. Provide power to drive(s) and press the green Run button on both drive(s) Ensure fan(s) are operating and rotating correct direction. 30 Hz should be displayed on drive(s) Manually adjust the vents to the desired opening for minimum ventilation. Adjust fan(s) speed using the up and down arrows ensuring to adjust both units (if 2 drives are present) until the desired static pressure is reached. Note the setting! This is now the minimum frequency setting for minimum ventilation. Depress the Red stop button Following the same method from above adjust the following settings for all supply voltages and frequencies P100 Start Control Source Set to (1) Terminal Strip P101 Standard Reference Source Set to (1) 0-10VDC Terminal Strop P102 Minimum Frequency Set to frequency determined above in minimum ventilation testing If two drives are present ensure both drives are set up the same. Drive set up is now complete and is set to automatic mode (controlled via whole house controller) *The 0-10 Volt signal supplied from the whole house controller must be modified (scaled) appropriately based on minimum ventilation testing. 60Hz Example if 30 hz is determined to be the minimum setting the 0-10V signal should become 5-10V signal. 30Hz/60Hz = .5 .5 X 10V = 5V 50Hz Example if 30 Hz is determined to be the minimum setting the 0-10V signal should become 6-10V signal. 30Hz/50Hz=.6 .6 X 10V= 6V

Hog Slat Inc. Newton Grove, NC August 2022 19 Air Storm Fans Back Up Thermostat Set Up The supplied Variable Frequency Drive is capable of accepting a backup signal to tell the drive to operate at a user defined speed if a condition is met. (Example a thermostat) The following steps and wiring diagram illustrate how to set this up. Connect back up signal device as shown below. Following the same method from above adjust the following settings P121 TB-13A Input Function Set to (3) Auto Reference: Preset 1 P125 Acceleration Time 2 Set to (7) Seconds P126 Deceleration Time 2 Set to (7) Seconds P131 Preset Speed #1 Set to desired override speed (60) Hz for full speed.

Hog Slat Inc. Newton Grove, NC August 2022 20 Air Storm Fans General Installation Notes: Make sure that power is disconnected from system prior to servicing. Installation of this equipment and related OEM equipment should be in accordance with these instructions, OEM’s installation instructions and local codes (if applicable). Failure to follow specified instructions may cause damage to equipment and/or personal injury or death. Take special note of any Warnings or Safety Decals on the equipment and in manuals. Always wear protective clothing and any applicable Personal Protective Equipment (Safety Glasses and/or Ear Plugs) when working with the equipment. Discarded materials, equipment and boxes should be recycled in accordance with local and national codes. Safety Instructions: Read all safety messages in this manual and on equipment safety decals. Follow recommended precautions and safe operating practices. Ground all electrical equipment for safety. Ground all non-current carrying metal parts to guard against electrical shock. Pre-Operation Assessment Before beginning fan operation, please follow the below checklist to ensure that:  Fan power cord securely connected to a good power supply.  All safety labels are visible to personnel that will work in the area.  Exit wire guard and inlet shutter are in place and secured to the fan housing.  No foreign objects are protruding through the fan housing. Operation At all times during operation, fan orifice should be free of debris. In the event any component of the fan is compromised, discontinue use immediately and contact your local Hog Slat representative.

Hog Slat Inc. Newton Grove, NC August 2022 21 Air Storm Fans Maintenance In order to begin any maintenance or service to the fan, power must be turned OFF and all moving parts must come to a complete STOP before accessing. All parts inside of the fan housing are accessed by removing the exit wire guard and inlet shutter. Once service is complete, clean excessive build-up from parts. Excessive dust and dirt on parts can cause vibration in the propeller and overheating of the motor. Before beginning operation again, ensure that all safeguards are back in place and all foreign objects are free from the area. DURING MAINTENANCE AND OPERATION THE FOLLING MUST BE MAINTAINED TO ENSURE PROPER PERFORMANCE AND TO EXTEND USABLE COMPONENT LIFE.  DRIVE COMPONENTS ALIGNMENT o Proper alignment of pulleys, tension arms, etc.. is required to avoid excessive belt and drive component wear. Failure to maintain correct alignment during maintenance will void warranty of drive components  A straight edge or laser alignment device should be utilized to check for alignment of drive components [! IMPORTANT ! If for any reason drive system components are removed/replaced or loosened; it is important to ensure that components are properly realigned to achieve proper performance and longevity ]  BELT TENSION AND DIRECTION (when applicable) o Proper belt tension and direction is critical to avoid excessive belt and drive component wear. Failure to maintain correct belt tension during operation or maintenance will void warranty of drive components.  Supplied belt tensioner should be used to ensure proper belt tension.  Correct operation occurs when the tension arm is operating at the second indicator mark  Correct belt direction (when applicable) can be determined by an indicator on the belt notating desired rotation direction

Hog Slat Inc. Newton Grove, NC August 2022 22 Air Storm Fans  PROPER V GROOVE MAINTAINCE o Proper V groove dimensions are critical to maintaining performance and eliminating excessive belt wear. Failure to maintain proper V groove dimension will void warranty of drive components.  V belt gauges should be utilized to check for correct V groove dimensions.  Alternatively belts location on pulley can be used. Correct dimensions should allow belt to ride slightly above the outermost diameter of the pulleys, if belt rides below outermost diameter, pulley(s) should be changed.

Hog Slat Inc. Newton Grove, NC August 2022 23 Air Storm Fans Please see below for direction regarding applying grease to pillow block bearings UCP20516G5 (Bearings shipped on Grower Select Fans) Grease Amount: (1) Stroke on most standard grease guns or 0.8 grams * Volume dispensed per stroke should be verified with grease gun manufacturer Grease Interval: Every 300 Hours of Operation Type of Grease: Lithium Based NLGI No.2 Note: ELECTRIC OR BATTERY POWERED GREASE GUNS SHOULD NOT BE USED AND MAY VOID WARRANTY! Troubleshooting Trouble Possible Cause(s) Corrective Action Excessive noise Worn motor bearing. Replace Damage to fan blade Replace prop Loose fasteners on motor or housing Tighten fasteners Excessive vibration Fan blade is out of balance due to dirt build-up. Clean entire unit Fan blade is out of balance due to damage Replace prop Insufficient airflow Intake or exhaust guards clogged with debris Clean entire unit Intake or exhaust blocked by foreign object Remove object from airflow path Fan won’t operate Open power supply circuit. Check wiring and reset circuit breaker Defective motor Reset motor, repair, or replace Motor overheats and nuisance trips Improper airflow due to clogged Inlet/Outlet Clean entire unit Motor or Fan prop has excessive debris build-up Clean entire unit

Hog Slat Inc. Newton Grove, NC August 2022 24 Air Storm Fans Performance Hog Slat Inc. takes great pride in supplying our customers with fans that meet or exceed their performance numbers. This is achieved by testing fans from the production line and continually working to maintain consistency in test data. AS-51EBDLP BESS TEST 18216 Static Pressure (in.H2O) Airflow (cfm) Rpm Volts Amps Watts cfm/Watt 0.00 27400 617 230.9 7.04 1558 17.6 0.05 26100 616 230.7 7.24 1583 16.5 0.10 24600 615 230.6 7.46 1631 15.1 0.15 22900 614 230.5 7.60 1672 13.7 0.20 20900 613 230.6 7.70 1696 12.3 0.25 17800 612 229.6 7.80 1711 10.4 0.30 15300 612 229.7 7.85 1722 8.9

Hog Slat Inc. Newton Grove, NC August 2022 25 Air Storm Fans FREQUENCY DRIVE CURVES

Hog Slat Inc. Newton Grove, NC August 2022 26 Air Storm Fans Exploded Diagrams/Replacement Parts Item Key Replacement Part Number Description FAN 2 HS900-51FA Prop 51" 3-Blade AS Fan ALL 5 101209-1-8 Shutter Pvc 53 7/8'' X 53 7/8'' ALL 6 PAK1041 Pulley AK104-1 ALL 7 HS903-3 Tensioner Rotary Assembly With Splash Guards ALL 8 PAK3458 Pulley AK34-5/8 ALL 9 HS9014C Motor 1.5 HP 1725 RPM 115/208-230V 50/60 Hz 56 FR 1 PH AS-51XEBDLP ASC-51XEBDLP N/S HS9314 Motor 1.5 HP 1725/1425 RPM 208-230/460V 60/50 Hz 3 Phase AS-51XEBDLP3 ASC-51XEBDLP3 N/S HS9314-VFD Motor 1-1/2HP 1725RPM 208-230/460V 3Ph 60/50Hz VFD AS-51XEBDLP-V ASC-51XEBDLP-V 19 ASC-51206 Cone 51" Poly AirStorm ALL 20 AS902-51 Guard Exit Airstorm AS-51206 ALL N/S HS903-7A Belt Power Twist Gray 2nd Gen (BOM Only) ALL N/S WS-HW1 Hardware Kit Shutter Retainer 8ct. ALL N/S WS-HW4XA Hardware Kit Cone Mounting 54" Fan X Frame Multi Piece ALL N/S HSFI-1002 Inverter Frequency 2HP 240V 0-500Hz NEMA4X Outdoor AS-51XEBDLP-V ASC-51XEBDLP-V For OSHA compliant guards, contact your local Hog Slat representative.

Hog Slat Inc. Newton Grove, NC August 2022 27 Air Storm Fans Hog Slat Limited Warranty (AirStorm AS-51X Series Fans) Hog Slat warrants products to be free from defects in material or workmanship for a period of twenty-four (24) months from the date of original purchase. Hog Slat will credit, repair, or replace, at its option any product deemed defective within this time period. Labor costs associated with the replacement or repair of the product are not covered by the Seller/Manufacturer. Conditions and Limitations 1. The product must be installed by and operated in accordance with the instructions published by the Seller/Manufacturer or Warranty will be void. 2. Warranty is void if all components are not original equipment supplied by the Seller/Manufacturer. 3. This product must be purchased from and installed by an authorized retailer/distributor or certified representative thereof or the Warranty will be void. 4. Malfunctions or failure resulting from misuse, abuse, negligence, alteration, accident, or lack of proper maintenance shall not be considered defects under the Warranty. 5. This Warranty applies only to components/systems for the care of poultry and livestock. Other applications in industry or commerce are not covered by this Warranty. 6. This Warranty applies only to the Original Purchaser of the product. The Seller/Manufacturer shall not be liable for any Consequential or Special Damage which any purchaser may suffer or claim to suffer as a result of any defect in the product. “Consequential” or “Special Damages” as used herein include, but are not limited to, lost or damaged products or goods, costs of transportation, lost sales, lost orders, lost income, increased overhead, labor and incidental costs and operational inefficiencies. THIS WARRANTY CONSTITUTES THE SELLER/MANUFACTURER’S ENTIRE AND SOLE WARRANTY AND THIS MANUFACTURER EXPRESSLY DISCLAIMS ANY AND ALL OTHER WARRANTIES, INCLUDING, BUT NOT LIMITED TO, EXPRESS AND IMPLIED WARRANTIES AS TO MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSES SOLD AND DESCRIPTION OR QUALITY OF THE PRODUCT FURNISHED HEREUNDER. Hog Slat Retailers/Distributors are not authorized to modify or extend the terms and conditions of this Warranty in any manner or to offer or grant any other warranties for GrowerSelect products in addition to those terms expressly stated above. An officer of Hog Slat must authorize any exceptions to this Warranty in writing. The Seller/Manufacturer reserves the right to change models and specifications at any time without notice or obligation to improve previous models.

Hog Slat Inc. Newton Grove, NC August 2022 28 Air Storm Fans This equipment must be installed in accordance with all State and Local Codes and applicable Regulations which should be followed in all cases. Authorities having jurisdiction should be consulted before installations are made. Hog Slat, Inc. PO Box 300 Newton Grove, NC 28366 Phone: (910) 594-0219 Fax: (910) 594-1392 www.hogslat.com Copyright © 2019 by Hog Slat, Inc. Part Number: HSManual-221 Rev A1 Market: Hog & Poultry

Hog Slat Inc. Newton Grove, NC August 2022 29 Air Storm Fans AS-51XEBDLP Ventilateur 129,5 cm (51 po) FdV 1,5 HP 1 725 tr/min 115/230 V 60 Hz uniquement sans cône AS-51XEBDLP3 Ventilateur 129,5 cm (51 po) FdV 1,5 HP 1 725 tr/min 230/430 V 3Ph 60 Hz uniquement sans cône AS-51XEBDLP-V Ventilateur 129,5 cm (51 po) FdV 1,5 HP 1 725 tr/min 230/430 VdF 1/3Ph entraînement intégré sans cône ASC-51XEBDLP Ventilateur 129,5 cm (51 po) FdV 1,5 HP 1 725 tr/min 115/230 V 60 Hz uniquement sans cône ASC-51XEBDLP3 Ventilateur 129,5 cm (51 po) FdV 1,5 HP 1 725 tr/min 230/430 V 3Ph 60 Hz uniquement sans cône ASC-51XEBDLP-V Ventilateur 129,5 cm (51 po) FdV 1,5 HP 1 725 tr/min 230/430 VdF 1/3Ph entraînement intégré sans cône

Hog Slat Inc. Newton Grove, NC August 2022 30 Air Storm Fans Page générale de GrowerSELECT Remarques générales d’installation : Assurez-vous que l’alimentation électrique est déconnectée du système avant toute intervention. L’installation de cet équipement et de tout équipement de fabricant d’origine connexe doit être réalisée conformément à ces instructions, à celles de l’équipement du fabricant d’origine et aux codes locaux (s’il y a lieu). Le manquement à suivre ces instructions peut causer des dommages à l’équipement et/ou des blessures corporelles ou la mort. Prenez note des étiquettes d’avertissement et de sécurité sur l’équipement et dans les manuels. Portez toujours des vêtements de protection et tout équipement de protection personnelle applicable (lunettes de protection et/ou bouche-oreilles) lors de toute intervention sur l’équipement. Les matériaux, l’équipement et les boîtes à éliminer doivent être recyclés conformément aux codes locaux et nationaux en vigueur Consignes de sécurité : Lisez tous les messages de sécurité qui figurent dans ce manuel et sur les étiquettes de sécurité de l’équipement. Respectez les précautions et les pratiques d’emploi sécuritaires recommandées. Mettez à la masse tout équipement électrique. Mettez à la masse toute pièce métallique non conductrice pour assurer une protection contre une décharge électrique. Gardez toujours en bon état les étiquettes de sécurité et remplacez-les si elles sont manquantes ou endommagées.

Hog Slat Inc. Newton Grove, NC August 2022 31 Air Storm Fans Sécurité Étiquettes d’avertissement Des autocollants d’avertissement ont été placés sur le matériel pour vous avertir de situations potentiellement dangereuses. Des précautions doivent être prises pour garder cette information intacte et facile à lire en tout temps. Remplacez les affichettes de sécurité manquantes ou endommagées. Symbole d’alerte de sécurité Ceci est un symbole d’alerte de sécurité. Ce symbole affiché sur l’équipement vous avise d’être vigilant pour éviter les blessures corporelles. L’équipement GrowerSelect est conçu pour être installé et fonctionner de la manière la plus sécuritaire possible. Toutefois, des risques existent toujours. Les autocollants de sécurité doivent être lus et bien compris par les personnes qui se trouvent à proximité du ventilateur. Les autocollants de sécurité doivent être visibles tant à l’’avant qu’à l’arrière du ventilateur. Si un autocollant manque ou est endommagé, veuillez contacter Hog Slat Inc. pour obtenir gratuitement un autocollant de rechange. Hog Slat Inc. 206 Fayetteville St. Newton Grove, NC 28366 Sans frais : 800 949-4647 Local : 910 594-0219 Les autocollants de sécurité ci-dessous doivent être représentés et visibles tant à l’avant qu’à l’arrière du ventilateur. Cette étiquette est identifiée par le numéro de pièce HSLABEL-080 dans le coin inférieur droit. AVERTISSEMENT - OBJETS PROJETÉS ET PIÈCES EN ROTATION Assurez-vous que les protections pour le ventilateur sont en place lorsqu’il est en fonction. Serrez fermement l’hélice à l’axe pour éviter tout glissement. Déconnectez l’alimentation électrique lors d’une inspection ou d’une intervention lorsque les protections ont été enlevées et que le personnel est exposé à l’hélice. AVERTISSEMENT – HAUTE TENSION Déconnectez l’alimentation électrique avant toute inspection ou intervention sur le matériel à moins d’instructions particulières à l’effet du contraire. Mettez à la masse tout équipement électrique. Tout câblage électrique doit être installé par un électricien compétent, conformément aux codes électriques locaux et nationaux. Mettez à la masse toute pièce métallique non conductrice pour assurer une protection contre une décharge électrique. À l’exception de la protection contre la surcharge du moteur, les disjoncteurs et la protection contre les surintensités ne sont pas fournis avec l’équipement.

Hog Slat Inc. Newton Grove, NC August 2022 32 Air Storm Fans Installation Le produit doit être inspecté avant toute installation pour déceler tout dommage survenu lors du transport. Tout dommage découvert doit être documenté et communiqué aux parties responsables. Sécurité de fonctionnement Lorsque le ventilateur est en marche, il ne faut jamais tenter d’intervention quelconque ou d’interaction avec des pièces du ventilateur. Toute tentative d’interaction avec des pièces du ventilateur lorsque ce dernier est en marche peut entraîner des blessures. Des protections d’entrée et de sortie et/ou des volets sont en place pour aider à empêcher les corps étrangers de pénétrer dans le périmètre extérieur du boîtier. Si une intervention d’entretien doit être effectuée sur le ventilateur, coupez la source d’alimentation au moteur et laissez l’hélice s’arrêter complètement avant de poursuivre toute tentative de service. Sécurité d’entretien Les ventilateurs AirStorm sont conçus et construits en pensant à la sécurité de l’opérateur. Certaines protections doivent être désassemblées ou enlevées pour assurer le service ou le remplacement des pièces. Puisque ce ventilateur comporte des pièces mobiles et qu’il est fourni avec une alimentation électrique, des mesures doivent être prises pour assurer la sécurité contre les risques présents. LISEZ CES INSTRUCTIONS AVANT D’EFFECTUER TOUTE INTERVENTION DE SERVICE OU DE REMPLACEMENT DES PIÈCES 6. Assurez-vous de lire et de bien comprendre le manuel d’emploi avant d’installer ou de faire fonctionner les ventilateurs AirStorm. 7. L’alimentation électrique doit être COUPÉE et VERROUILLÉE pour effectuer toute intervention sur le moteur et les composants électriques. Faites preuve de PRUDENCE lors de la vérification de la tension ou de toute autre intervention exigeant que l’appareil soit sous tension. 8. NE tentez PAS de contourner une caractéristique de sécurité ou un dispositif pour faire fonctionner le ventilateur. 9. Gardez le ventilateur libre des débris qui peuvent s’accumuler sur le moteur, l’hélice, les roulements, courroies ou poulies. 10. Faites preuve de PRUDENCE lors du travail autour des pièces mobiles du ventilateur. Les protections ou volets du ventilateur doivent être en place avant que le ventilateur puisse être mis en marche et fonctionnel de manière sécuritaire. Installation Ossature L’ouverture brute pour le ventilateur est une mesure exacte qui tient compte des têtes de fixation et des ouvertures pour le ventilateur. Assurez un dégagement suffisant pour l’installation ou des mesures plus grandes pourraient être nécessaires à l’ouverture brute. Modèle de ventilateur Ouverture brute (largeur sur hauteur) Ventilateur d’extraction en fibre de verre de 35,5 cm (51 po) 139,7 cm x 139,7 cm (55 po x 55 po) Consultez le schéma à la page suivante pour les mesures particulières de l’épaisseur du mur

Hog Slat Inc. Newton Grove, NC August 2022 33 Air Storm Fans ! Dans certaines applications, l’inclinaison du boîtier du ventilateur exige que le matériau de finition extérieur s’étende de 19 mm (3/4 po) sous le sommet de l’ouverture brute!

Hog Slat Inc. Newton Grove, NC August 2022 34 Air Storm Fans Assemblage 5. Retirez l’emballage du ventilateur et du cône, s’il y a lieu.  Trouvez la ou les trousses de visserie et la documentation fournie et rangez-les pour un usage ultérieur.  Assurez-vous de ne pas endommager le ventilateur ou ses composants pendant cette étape. 6. Déposez les volets du boîtier du ventilateur puis, de l’intérieur du bâtiment, insérez le capot de refoulement du ventilateur dans l’ouverture brute. 7. Avec les vis en métal no 14 fournies (805060), fixez le boîtier au cadre.  L’utilisation de huit fixations est recommandée pour bien fixer le ventilateur. Chaque coin doit être fixé, de même que le point central entre chaque coin.  Vérifiez qu’il y a suffisamment d’espace à l’intérieur des fixations pour assurer le montage affleurant des volets au boîtier du ventilateur.

Hog Slat Inc. Newton Grove, NC August 2022 35 Air Storm Fans Montage du cône monopièce OPTION 1 10 Insérez le cône sur l’orifice du boîtier du ventilateur.  Alignez les trous prépercés dans le cône sur ceux des supports du cône et fixez avec les boulons de 5/16 po x 1 po, rondelles et contre-écrous en acier inoxydable fournis.  Des trous fendus sont fournis dans le cône pour faciliter l’installation.

Hog Slat Inc. Newton Grove, NC August 2022 36 Air Storm Fans OPTION 2 8. Insérez le cône sur l’orifice du boîtier du ventilateur.  Alignez les trous prépercés dans le cône sur ceux du boîtier et fixez le cône sur le boîtier.  Des trous fendus sont fournis dans le cône pour faciliter l’installation.  Assemblez comme montré ci-dessous avec les boulons à tête plate, les contre-écrous et les rondelles larges.  ! LES BOULONS À TÊTE PLATE DOIVENT ÊTRE INSTALLÉS DE MANIÈRE À AFFLEURER LE BOÎTIER AVEC LES CONTRE-ÉCROUS ET LES RONDELLES À L’EXTÉRIEUR DU CÔNE!

Hog Slat Inc. Newton Grove, NC August 2022 37 Air Storm Fans 11 Placez la protection de sortie du ventilateur sur la bride de sortie du cône, comme montré ci-dessous.  Fixez avec les fixations fournies, la tête du boulon faisant face au bâtiment et les écrous à embase étant orientés à l’opposé du ventilateur. 12 Avec une mèche de 12,7 mm (1/2 po), percez un trou de secours dans le boîtier à l’endroit désiré pour y faire passer le cordon d’alimentation.  ! ASSUREZ-VOUS QUE L’EMPLACEMENT DU TROU NE PERMETTE PAS AU CORDON D’ALIMENTATION DE SE TROUVER À PROXIMITÉ DE LA ROTATION DES PALES DU VENTILATEUR OU DE L’ACTION DES VOLETS!  Assurez-vous également que l’emplacement du trou ne laisse pas entrer trop d’eau lors des intempéries.  L’illustration fournie n’est qu’une recommandation! Le point d’entrée réel de l’alimentation électrique doit être déterminé par l’installateur. 13 Un second trou de secours est recommandé dans la plupart des applications au bas du boîtier pour évacuer tout liquide qui pourrait s’y accumuler. Ce trou doit être percé à la base du boîtier et centré entre le support vertical et la sortie de l’orifice.

Hog Slat Inc. Newton Grove, NC August 2022 38 Air Storm Fans 14 De l’intérieur du boîtier, servez-vous du contenu de l’ensemble de visserie WS-001 pour fixer les volets à l’ouverture d’entrée du ventilateur. Placez les volets dans l’ouverture d’entrée du ventilateur. Assurezvous que les volets sont orientés de manière à basculer vers le haut lorsque l’air circule de l’intérieur du bâtiment par le ventilateur vers l’extérieur. DES TROUS ONT ÉTÉ PRÉPERCÉS DANS LE BOÎTIER POUR LES 2 AGRAFES DE RETENUE DU BAS DE MANIÈRE À GARANTIR QUE LES VOLETS SOIENT CENTRÉS. CHAQUE TROU PRÉPERCÉ EST ASSORTI D’UNE DÉCALCOMANIE INDIQUANT LA FONCTION DU TROU. 15 Fixez huit (8) agrafes de retenue des volets avec une rondelle en aluminium et une vis autotaraudeuse au boîtier du ventilateur. Espacez uniformément les agrafes de retenue entre les vis de fixation appliquées à l’étape 2. CELA COMPLÈTE L’ASSEMBLAGE DU BOÎTIER DU VENTILATEUR

Hog Slat Inc. Newton Grove, NC August 2022 39 Air Storm Fans Câblage Pour accéder au moteur, tournez les agrafes de retenue des volets de manière à pouvoir enlever les volets. Une fois de plus, assurez-vous que l’alimentation électrique est déconnectée du système avant toute intervention. Assurez toujours une rotation appropriée de l’hélice après avoir installé ou remplacé le moteur. Lors du fonctionnement de l’appareil, l’air doit être dirigé de l’intérieur du bâtiment vers l’extérieur. SUIVEZ TOUJOURS LE SCHÉMA DE CÂBLAGE FOURNI SUR LE MOTEUR! DANGER DE DÉCHARGE ÉLECTRIQUE!  Le remplacement du moteur et les changements de câblage qui y sont associés doivent être effectués uniquement par des personnes compétentes et dûment formées.  Le non-respect de l’avertissement ci-dessus peut causer un mauvais fonctionnement de l’équipement, une défaillance prématurée ou une décharge électrique, entraînant des dommages matériels ou des blessures corporelles. Monophasé (câblage de 230 V) Triphasé (câblage de 230/460 V) Notez la rotation, si un changement est nécessaire, inversez les colonnes (L1, L2 ou L3).

Hog Slat Inc. Newton Grove, NC August 2022 40 Air Storm Fans Si vous avez acheté un produit avec un moteur à variateur de fréquence, lisez ci-dessous! Les moteurs suivants NE contiennent PAS de protection thermique interne. Ils sont prévus pour être utilisés en conjonction avec un entraînement à fréquence variable (indiqués dans le tableau ci-dessous). Si l’un des moteurs indiqués ci-dessous est utilisé dans une application où il n’est pas directement commandé par un variateur de fréquence, alors L’INSTALLATION/VALIDATION D’UNE PROTECTION THERMIQUE EXTERNE EST EXIGÉE! LA PROTECTION THERMIQUE EXTERNE DOIT AVOIR UN CALIBRE APPROPRIÉ Veuillez consulter la norme NEC 430.31/430.32/430.40 pour de l’information supplémentaire concernant le calibre de la protection contre les surcharges. Moteur Variateur HS9308-VFD HSFI-1001 HS9306A-VFD HSFI-1001 HS9309-VFD HSFI-1001 HS9314-VFD HSFI-1002 HS9378-VFD HSFI-1002 Remarque : Lors de la détermination du calibre des fils et/ou de la capacité des fusibles et de la disposition des ventilateurs à conversion de phase (monophasé à triphasé), rappelez-vous que la détermination doit être faite en fonction du débit en ampères du dispositif d’entraînement et non pas du moteur. Des exemples sont montrés ci-dessous. Le calibre des fils doit être approprié de manière à correspondre à l’ampérage nominal d’entrée du dispositif d’entraînement. Le produit est prévu pour être installé conformément à tous les codes locaux et nationaux. Numéro de modèle de ventilateur Intensité nominale d’entrée AS-14EDDLP-V 8,8 A AS-18EDDLP-V 8,8 A AS-24EDDLP-V 8,8 A AS-36EDDLPA-V 8,8 A AS-54XEBDLP-V 13,3A AS-57EBDBP-V 13,3 A AS-57EBDBPG-V 13,3 A AS-54EDDLP-ID 20,0 A WS-F52B2A-V 13,3 A WS-54SBDLA-V 13,3 A WS-54PBDBG-V 13,3 A

Hog Slat Inc. Newton Grove, NC August 2022 41 Air Storm Fans .

Hog Slat Inc. Newton Grove, NC August 2022 42 Air Storm Fans

Hog Slat Inc. Newton Grove, NC August 2022 43 Air Storm Fans Configuration initiale. Les réglages suivants doivent être faits initialement au dispositif d’entraînement. La source de démarrage, la référence standard et le réglage de la fréquence minimale doivent être réglés à la suite d’un essai de ventilation minimale. Afin de régler les paramètres, mettez sous tension le dispositif d’entraînement et enfoncez le bouton bleu M pour accéder au menu des points de réglage. Un exemple est fourni ci-dessous. Pour accéder aux paramètres ou modifier ceux-ci, enfoncez le bouton bleu M en vous servant des touches fléchées vers le haut et le bas pour défiler jusqu’au paramètre désiré à l’écran. Enfoncez le bouton bleu M pour sélectionner le paramètre en vous servant des touches fléchées pour saisir la valeur désirée. Lorsque la valeur désirée s’affiche, enfoncez le bouton bleu M une fois de plus pour enregistrer le paramètre. Servez-vous des touches fléchées pour passer au prochain paramètre. Paramètre Alimentation 60 Hz (208-240 V) Alimentation 50 Hz (208-240 V) P100 Source de commande de démarrage 0 0 P101 Source de référence standard 0 0 P102 Fréquence minimale 30 30 P103 Fréquence maximale 60 50 P104 Temps d’accélération 7 7 P105 Temps de décélération 7 7 P110 Méthode de démarrage 5 5 P152 Fréquence d’échelonnage 60 50 P161 Vitesse à fréquence max. 60 50 P302 Tension nominale du moteur 230 220 P303 Courant nominal du moteur Courant à pleine charge du moteur @230 V 60 Hz Courant à pleine charge du moteur @220 V 60 Hz P304 Fréquence nominale du moteur 60 50 P305 Vitesse nominale du moteur Régime du moteur @ 60 Hz Régime du moteur @ 50 Hz POUR RÉINITIALISER L’ENTRAÎNEMENT AUX PARAMÈTRES D’USINE, CHANGEZ LE PARAMÈTREP199 À 03 (Pour 60 Hz) OU 04 (Pour 50 Hz)