GrowerSELECT - AS-54XEDDLP-ID AirStorm 54 Inch Inf Drive Fan Manual

Hog Slat Inc. Newton Grove, NC USA August 2019 13 Air Storm Fans when the drain plugs (located at 6 o’clock on both ends of the frame) are inserted correctly. ! REMOVE THE DRAIN PLUGS ONCE A YEAR TO ENSURE THE MOTOR IS DRAINED PROPERLY ! RATING All associated documentation applies to 3HP model designed to operate from 1Φ, 230 Vac, 60/50Hz. Rated Shaft Output Power: 3HP Rated Speed: 750 RPM Unloaded (In application rated speed: 686) Rated System Input Current: 17.0 Amps Protection and Faults: Locked Rotor Fault: The drive trips until electrical power is removed or speed demand is set to zero, and the issue is resolved. Example: Item lodged in fan not allowing impeller to rotate, the drive will trip and must be manually reset once obstruction is removed. Output Overcurrent: Motor performance is reduced until the current returns to normal operating parameters. If the motor is unable to reach normal operating current by reducing performance the drive will trip. Example: Opposing wind gust cause the amp draw to spike, the drive will reduce speed until the current returns to an acceptable level, once wind reduces drive returns to normal operation. Over Temperature: The drive trips until power module temperature returns to normal operating parameters and then will restart automatically. Example: Motor overheats and drive trips, once motor cools to acceptable level the drive automatically restarts.

RkJQdWJsaXNoZXIy MTA3MzU=