Hog Slat Inc. Newton Grove, NC USA August 2019 20 Air Storm Fans After jumpers and/or control signal is wired max speed can be set by adjust the MAX trimpot. Turn trimpot clockwise to increase speed, counter clockwise to reduce speed. ! PROPER SAFTEY MEASURES SHOULD BE USED WHEN ADJSUTING SPEED. ALWAYS OPERATE FAN WITH GUARDS AND PROTECTIVE EQUIPMENT IN PLACE ! Pre-Operation Assessment Before beginning fan operation, please follow the below checklist to ensure that: Fan power cord securely connected to a good power supply. All safety labels are visible to personnel that will work in the area. Exit wire guard and inlet shutter are in place and secured to the fan housing. No foreign objects are protruding through the fan housing. Operation At all times during operation, fan orifice should be free of debris. In the event any component of the fan is compromised, discontinue use immediately and contact your local Hog Slat representative.