GrowerSELECT - AS-54XEDDLP-ID AirStorm 54 Inch Inf Drive Fan Manual

Hog Slat Inc. Newton Grove, NC USA August 2019 9 Air Storm Fans 4 Place the fan exit guard onto the outlet flange of the cone as shown below.  Secure with supplied fasteners with the bolt head facing the building and flange nuts facing away from fan. 5 Using a 1/2” drill bit, drill a relief hole in the housing at desired location for entry of power cord.  ! ENSURE HOLE LOCATION WILL NOT ALLOW POWER CORD TO APPROACH THE PATH OF THE ROTATING FAN BLADE OR SHUTTER ACTION!  Also ensure hole location will not allow excessive entry of water during adverse weather conditions  Image shown is recommendation only! Actual point of power entry should be determined by installer. 6 A second relief hole is recommended in most applications in the bottom of the housing to allow drainage of any liquid that could accumulate in the bottom of the housing. This hole should be drilled in base of the housing centered between the vertical support and orifice exit.