GrowerSelect GROW-FLEX Auger Feed System Installation Operation Manual

Hog Slat Inc. Newton Grove, NC USA August 2021 23 Grow-FlexTM Feed System HS593 Feed Line Control Unit – 240V Single Phase Note: Control Unit is to be wired in accordance with all applicable local and national electrical wiring codes. All wiring sizes and fuse capacities are to be sized according to applicable electrical code specifications or other regulations. Safety Instructions: Read all safety messages in this manual and on equipment safety decals. Follow recommended precautions and safe operating practices. Ground all electrical equipment for safety. Ground all non-current carrying metal parts to guard against electrical shock. Always keep safety decals in good condition and replace missing or damaged decals. Overview: The GrowerSELECT HS593 Control Unit is designed for use with a flexible auger feed system where control of an auger drive motor is required. Power to the auger drive motor is done through feed pressure being applied to a diaphragm coupled to an electrical switch internal to the control unit housing. This switch is used to control the auger drive motor by turning off the power when feed is present and turning on the power when feed has been removed from the control unit housing. The sensitivity of the electrical switch is not adjustable. MAXIMUM LOAD RATING: 1 ½ HP @ 230VAC A red indicator light on the side of the switch housing will illuminate when the diaphragm has been pressed (MOTOR OFF) and the switch has been activated. The ON/OFF switch is used to enable or disable the Control Unit. DO NOT USE THIS SWITCH AS DISCONNECTING MEANS FOR SERVICING.

RkJQdWJsaXNoZXIy MTA3MzU=