GrowerSelect GROW-FLEX Auger Feed System Installation Operation Manual

Hog Slat Inc. Newton Grove, NC USA August 2021 28 Grow-FlexTM Feed System Wiring Instructions Installation in four (4) wire control systems: Installation should be consistent with existing sensor wiring and OEM’s recommendations. Use the chart below to determine correct lead connection point for the HS10 per OEM’s sensor configuration. Note: The Hog Slat, HS10, leads should be connected to the same location as the replaced OEM sensor’s lead per this chart (Figure 2) Lead HS10 Normally Closed (NC) Black 3 Normally Open (NO) Black 4 Normally not used Common Black 1 L1 Brown L2 Blue Figure 2 Note: Any wire(s) not used must be taped (insulated) for protection! Operating Instructions: All settings should be made with Product (Grain or Feed) not in contact with sensor (Sensor is not Activated). Figure 4 Setting Time Delay (Factory setting is 30 seconds) 1. Press Buttons “A” & “B” simultaneously twice (2) until Mode LED is Red 2. Press and Release Button A once for each minute of delay desired 3. Press and Release Button B once for each second of delay desired 4. To exit Time Delay Program Mode, Press Buttons “A” & “B” simultaneously once 5. Red Program Mode LED will go off

RkJQdWJsaXNoZXIy MTA3MzU=