Hog Slat Inc. Newton Grove, NC USA August 2021 43 Grow-FlexTM Feed System Auger Brazing If the auger needs to be spliced or lengthened, locate the brazed joint closer to the power unit to minimize feed flow restriction in the line. To align the auger for brazing, lay it in angle iron and clamp securely. Rotate the auger to allow both the inside and outside edges of the augers to be brazed. Place the ends of the auger against each other. DO NOT SCREW ONE AUGER INSIDE THE OTHER- - This restricts the feed flow. Figure 23 and the associated chart specify how far to lap the augers. A bronze, flux-coated rod is recommended. The joint should be well filled and smooth so that it does not wear against the tube. Allow the joint to air cool. File the auger edges, as shown in Figure 24, to avoid damage to the auger tubes. Also, file off any brazing that extended beyond the outside radius of the auger flightings. Figure 23. Auger Brazing Auger Overlap Distance Model 55 Model 75 & Model HR Model 90 1.0” to 1.125” 1.5” to 1.75” 1.5” to 1.75” 25 to 29 mm 38 to 45 mm 38 to 45 mm Figure 24. File all sharp edges at brazed connections.