GrowerSELECT - HS09 Replacement Feed Sensor Installation & Operation Instructions

Hog Slat Inc. Newton Grove, NC USA September 2019 2 Grow-FlexTM Feed System Wiring: Installation in four (4) wire control systems: Installation should be consistent with existing sensor wiring and OEM’s recommendations. Use the chart below to determine correct lead connection point for the HS09 per OEM’s sensor configuration. Note: The Hog Slat, HS09, leads should be connected to the same location as the replaced OEM sensor’s lead per this chart (Figure 2) Hog Slat CTB AP Lead HS09 34255 1002 Normally Closed (NC) Black 3 Black 3 Red Normally Open (NO) Black 4 Black 4 Orange Normally not used Common Black 1 Black 1 Green L2 Blue Blue Black L1 Brown Brown Brown Figure 2 Note: Any wire(s) not used must be taped (insulated) for protection! Adjustment: The time delay and sensitivity can be adjusted with the small supplied screwdriver. Locate adjustment potentiometers on the side of the sensor near the corded ended. Delay range is 1 second to10 minutes. Clockwise to increase delay Sensitivity range is 0-10/16 [15MM]. Clockwise to increase sensitivity Figure 3 Operating Instructions: All settings should be made with Product (Grain or Feed) not in contact with sensor (Sensor is not Activated). The HS09 has a time delay. The relay switches as soon as the sensor is activated (detects grain or feed), but when the activation ceased, there is a delay before the relay switches back. The red LED indicates the status of the sensor and the relay. • Steady Light-Sensor not activated • No Light-Sensor activated • Quick Flashing-Short time delay • Slow Flashing-Long time delay

RkJQdWJsaXNoZXIy MTA3MzU=