Hog Slat Inc. Newton Grove, NC USA September 2019 3 Grow-FlexTM Feed System Setting Sensitivity (Factory setting is 1/4”, for grain) 1. Press Buttons “A” & “B” simultaneously once until Mode LED is Green 2. Press and Release Button A will decrease sensitivity by 1/32” 3. Press and Release Button B will increase sensitivity by 1/32” 4. To exit Time Delay Program Mode, Press Buttons “A” & “B” simultaneously twice (2) 5. Green Program Mode LED will turn Red then go off. Setting Special Functions 1. Reset to Factory setting for Sensitivity and Delay Press Button “A” & “B” simultaneously and hold for 15 seconds until both LEDs turn “yellow.” 2. Show Delay • Press and hold button “A” and then press button “B” twice (2). Mode LED will flash Red once for each minute of delay, flash Green once for each second of delay and flash Yellow once for each hour of delay. (For example: 1 Red flash and 2 Green flashes indicate 1 minute and 2 second delay) 3. Switch Off Delay Press and hold Button “A” and then press Button “B” seven (7) times General Operating Considerations When Product (Feed) is Detected • NC Contacts—Open • NO contacts— Close • Status LED turns Red and stays on until Product is Removed When Product (Feed) is Removed • Time Delay Begins for programmed amount of time • Status LED will flash Red until Delay expires. When Time Delay expires • NC Contacts—Close • NO contacts—Open • Status LED stops flashing and turns Green until Product is Detected When Status LED is Yellow • There is an Error in Sensor HSART-392 Rev A2 Market: Hog
RkJQdWJsaXNoZXIy MTA3MzU=