GrowerSELECT HS529 Hopper Level Control English Spanish Parts Wiring Installation Instructions

Hog Slat Inc. Newton Grove, NC USA September 2019 Rev A8 1 Grow-FlexTM Feed System HS529 Hopper Level Control (Includes Spanish Version - Incluye versión en español) (Includes French Version - Comprend la version française) Part List · Wiring · Installation General Installation Notes: Make sure that power is disconnected from system prior to servicing. Installation of this equipment and related OEM equipment should be in accordance with these instructions, OEM’s installation instructions and local codes (if applicable). Failure to follow specified instructions may cause damage to equipment and/or personal injury or death. Take special note of any Warnings or Safety Decals on the equipment and in manuals. Always wear protective clothing and any applicable Personal Protective Equipment (Safety Glasses and/or Ear Plugs) when working with the equipment. Discarded materials, equipment and boxes should be recycled in accordance with local and national codes. Unless otherwise specified, all Feed Delivery Systems (Diameters) are installed similarly. Do not connect rigid conduit to enclosure (switch box housing – item 7 of parts list). Overview: The HS529 Hopper Level Control is a universal control intended to be used with any conveying system that carries free-flowing feed. The control will automatically start or stop the fill system as the feed level pressure against the paddle assembly changes. Controls may be used in more than one hopper to ensure that no hopper runs out of feed before the control unit hopper requires feed. In applications where more than one control unit are used, the Control Units must be wired in Parallel so that any unit can start the system. The HS529 is suitable for use in both Poultry and Hog applications. Poultry Applications Hopper Level Control installed in the end or last hopper of Delivery System should be installed Low.

Hog Slat Inc. Newton Grove, NC USA September 2019 Rev A8 2 Grow-FlexTM Feed System Hog Applications For the majority of Hog Installations, the Hopper Level Control is installed in the last hopper that is located at the end of the Delivery System. Installation: The HS529 Hopper Level Control should be installed in the last hopper or feeder which is located at the end of the delivery or fill system. The unit should be mounted low in the hopper or feeder so the fill level in the control hopper will be lower than the others. This will cause the fill system to cycle more frequently insuring a proper feed level in every hopper or feeder. It will also provide a reservoir of feed in the system if another control hopper calls for feed. The feed drop tube should be positioned so that feed is delivered to the center and near the top of the control in front of paddle. Drop tubes and other control units should be positioned high in other hoppers or feeders so that they will fill but not overflow. Important: The HS529 must be mounted vertically to ensure the proper movement of the switch and paddle assembly. HS529 Hopper Level Control Mounted Vertically Determine the desired placement of the Control Unit and drill (2) 9/32” (7.2mm) diameter holes using the Mounting Bracket as a guide to determine hole spacing. Assemble the mounting bracket using the supplier ¼- 20 hex bolts and lock nuts. (For those applications where there is not a suitable vertical surface on the hopper or feeder; the Mounting Bracket should be bent or formed to ensure the Control unit is completely vertical when installed into the Mounting Bracket.) Install the Control Unit into the mounting bracket. Note: The mounting bracket bolted directly to the Control Unit can be shifted between the two sets of screws to achieve the optimum location within the hopper or feeder. The two sets of screws are approximately 2” (50mm) apart.

Hog Slat Inc. Newton Grove, NC USA September 2019 Rev A8 3 Grow-FlexTM Feed System Wiring: IMPORTANT Disconnect all electrical power before attempting installation of this (or any equipment), inspecting or servicing. Ground all electrical equipment in accordance with applicable codes. Do not assume equipment will automatically be grounded due to incidental metal-to-metal contact. ALL electrical wiring must be done by a qualified electrician in accordance with local and national electric codes. The HS529 Hopper Level Control is a single pole, double throw switch connects so that the circuit is normally closed (Motor Runs) when there is no feed present against the paddle. The circuit is open (Motor Stops) when there is feed against the paddle. The HS529 internal switch is rated for 20 amps (Approximately 1 HP). It can be directly connected in series to control a motor with less current requirement than 20 amps. If the motor current is greater than 20 amps, the Control Unit must be connected to a relay/contactor. Wiring for use with GrowerSELECT HS593 Control unit or CTB 6500 Control Unit DANGER: Electrical Hazard

Hog Slat Inc. Newton Grove, NC USA September 2019 Rev A8 4 Grow-FlexTM Feed System For applications involving the use of HS529 Hopper Level Control with AP’s FLX-4496 and FLX-4520 Controllers; the included jumper and wire nut kit must be used for direct connection to the AP units. Wiring for use with AP FLX-4496 or FLX-4520 Switch and Paddle Adjustment: The Hopper Control is set at the factory for Switch Sensitivity and Paddle Position for average feed weight and consistency. It is normal for the installer to make some fine tune adjustments based on actual feed weight and consistency. Important: The External Adjustment Nut is for paddle position only. Switch sensitivity can only be adjusted internally. Paddle Positioning 1. Place Control Unit in a vertical position with NO FEED in front of paddle. 2. Turn external nut CLOCKWISE until switch actuates (clicks). 3. Turn nut back COUNTER-CLOCKWISE until switch de-activates (clicks). 4. Turn nut TWO (2) additional full turns COUNTER-CLOCKWISE. Switch Sensitivity Adjustment: 1. Remove four (4) screws and lid from white control box on Control Unit. 2. Loosen the two (2) #6 slotted, hex washer head screws securing switch bracket inside white box. 3. Slide switch and bracket assembly accordingly: a. RIGHT to make unit Less Sensitive, requiring more feed to actuate b. LEFT to make More Sensitive, requiring less feed to actuate. 4. Re-tighten screws (do not over-tighten and strip) 5. Important: Paddle Position must be re-adjusted whenever switch sensitivity is adjusted.

Hog Slat Inc. Newton Grove, NC USA September 2019 Rev A8 5 Grow-FlexTM Feed System HS529 Hopper Level Control Part Listing 4 Flapper, Shield HS529-7 14 Gasker, Box HS529-49 5 Shield, Rear HS529-8 15 Spring, Adjustment HS529-58 6 Cover, Hopper HS529-9 16 Nut, Nyloc 10-32 SS 1170858 7 Housing, Switch Box HS529-43 17 Switch, Modified EL1052M 8 Bracket, Mount HS529-16 18 Connector Liquid Tight Nylon 1/2' 61646 9 Insulation, Switch HS529-50 19 Pigtail, 10' with Terminals HSPT-005 10 Plunger, 1" HS529-46 20 Bracket, Mounting HS529-19

Hog Slat Inc. Newton Grove, NC USA September 2019 Rev A8 6 Grow-FlexTM Feed System Hog Slat Limited Warranty (HS529 Hopper Level Control) GrowerSelect Hopper Level Control is warranted to be free from defects in material or workmanship for a period of twenty-four (24) months from the date of original purchase of the Control. Hog Slat will credit, repair, or replace, at its option any Control deemed defective within this time period. Labor costs associated with the replacement or repair of the product are not covered by the Seller/Manufacturer. Conditions and Limitations 1. The product must be installed by and operated in accordance with the instructions published by the Seller/Manufacturer or Warranty will be void. 2. Warranty is void if all components of the Hopper Level Control are not original equipment supplied by the Seller/Manufacturer. 3. This product must be purchased from and installed by an authorized retailer/distributor or certified representative thereof or the Warranty will be void. 4. Malfunctions or failure resulting from misuse, abuse, negligence, alteration, accident, or lack of proper maintenance shall not be considered defects under the Warranty. 5. This Warranty applies only to components/systems for the care of poultry and livestock. Other applications in industry or commerce are not covered by this Warranty. 6. This Warranty applies only to the Original Purchaser of the product. The Seller/Manufacturer shall not be liable for any Consequential or Special Damage which any purchaser may suffer or claim to suffer as a result of any defect in the product. “Consequential” or “Special Damages” as used herein include, but are not limited to, lost or damaged products or goods, costs of transportation, lost sales, lost orders, lost income, increased overhead, labor and incidental costs and operational inefficiencies. THIS WARRANTY CONSTITUTES THE SELLER/MANUFACTURER’S ENTIRE AND SOLE WARRANTY AND THIS MANUFACTURER EXPRESSLY DISCLAIMS ANY AND ALL OTHER WARRANTIES, INCLUDING, BUT NOT LIMITED TO, EXPRESS AND IMPLIED WARRANTIES AS TO MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSES SOLD AND DESCRIPTION OR QUALITY OF THE PRODUCT FURNISHED HEREUNDER. Hog Slat Retailers/Distributors are not authorized to modify or extend the terms and conditions of this Warranty in any manner or to offer or grant any other warranties for GrowerSelect products in addition to those terms expressly stated above. An officer of Hog Slat must authorize any exceptions to this Warranty in writing. The Seller/Manufacturer reserves the right to change models and specifications at any time without notice or obligation to improve previous models.

Hog Slat Inc. Newton Grove, NC USA September 2019 Rev A8 7 Grow-FlexTM Feed System This Page Intentionally Left Blank

Hog Slat Inc. Newton Grove, NC USA September 2019 Rev A8 8 Grow-FlexTM Feed System This equipment must be installed in accordance with all State and Local Codes and applicable Regulations which should be followed in all cases. Authorities having jurisdiction should be consulted before installations are made. Hog Slat, Inc. PO Box 300 Newton Grove, NC 28366 Phone: (910) 594-0219 Fax: (910) 594-1392 www.hogslat.com Copyright © 2012 by Hog Slat, Inc

Hog Slat Inc. Newton Grove, NC USA September 2019 Rev A8 9 Grow-FlexTM Feed System HS529 Control de Nivel de Tolva Lista de Piezas · Alambrado · Instalación Notas Generales de Instalación: Asegúrese que la energía este desconectada del sistema antes de darle servicio. La instalación de este equipo y equipo OEM relacionado tendrá que estar en acuerdo con estas instrucciones, las instrucciones de instalación OEM y los códigos locales (si son aplicables). Si no se siguen las instrucciones especificadas podría causar daño al equipo y/o lesiones a las personas o causar hasta la muerte. Preste especial atención a todas las Advertencias o Rotulación de Seguridad que están en el equipo y en los manuales. Siempre use ropa protectora y cualquier Equipo de Protección Personal aplicable (gafas de seguridad y/o tapones de oídos) cuando se trabaja con el equipo. Materiales desechados, los equipos y las cajas deberán ser reciclados de acuerdo con los códigos locales y nacionales. A menos que se especifique lo contrario, todos los Sistemas de Distribución de Alimento (diámetros) se instalan de manera similar. No conectar el conducto rígido a la caja (caja de alojamiento de interruptor-articulo 7 en la lista de piezas. Información General : HS529 Control de Nivel de Tolva es un control universal destinado a ser utilizado con cualquier sistema transportador de alimento de flujo libre. El control encenderá o detendrá automáticamente el sistema de llenado cuando se den cambios de nivel de presión del alimento en el pedal ensamblado. Los controles pueden ser usados en más de una tolva para asegurarse que ningua tolva quede sin alimento antes que el control de nivel de tolva requiera ser llenado de alimento. En aplicaciones donde más de un control de unidad son usados, el Control de Unidad deberá ser alambrado Paralelo para que así cualquier unidad tenga la capacidad de encender el sistema. El HS529 es adecuado para uso tanto en aplicaciones con aves de corral como porcícolas. Aplicaciones para Aves Control de Nivel de Tolva instalada al final o en ultima tolva del Sistema de Distribucion debe ser instalado Bajo.

Hog Slat Inc. Newton Grove, NC USA September 2019 Rev A8 10 Grow-FlexTM Feed System Aplicaciones para Porcicultura P Para la mayoría de las instalaciones Porcicolas, el Control de Nivel de Tolva es instalado en la última tolva el cual esta localizado al final del Sistema de Distribución Instalación: El Control de Nivel de Tolva HS529 debe ser instalado en la última tolva o comedero el cual es localizado al final del sistema de distribución o sistema de llenado de alimento. Las unidades deberán ser instaladas bajas en la tolva o comedero, de esa manera el nivel de llenado en la tolva de control será más bajo que en las otras. Esto tendrá como consecuencia que el sitema de llenado tenga más ciclos más frecuentemente asegurando así un nivel de alimento apropiado en cada tolva o comedero. También proporcinara un depósito de alimento en el sistema si otro control de tolva exige alimento. El tubo de caída de alimemto deberá ser colocado de manera que el alimento sea depositado al centro y cerca de la parte superior del control frente al pedal. Tubos de caída y otras unidades de control deberán ser colocadas altas en otras tolvas o comederos de manera que se puedan llenar sin derramarse. Importante: El HS529 debe ser instalado verticalmente para asegurar el movimiento apropiado del interruptor y del pedal ensamblado. HS529 Control de Nivel de Tolva Instalado Verticalmente Determinar la ubicación deseada de la Unidad de Control y perforar con un taladro (2) orificios de 9/32” (7.2mm) de diámetro usando el soporte de montaje o instalación como guía para determinar la distancia entre los orificios. Ensamble el soporte de montaje usando los ¼-20 tornillos exagonales y tuercas de fijación. (Para aquellas aplicaciones donde no existe una superficie vertical en la tolva o comedero; el Soporte de Montaje se debe doblar o acomodar para asegurar que la Unidad de Control este completamente vertical cuando se instale en el Soporte de Montaje.) Instalar la Unidad de Control en el Soporte de Montaje. Nota: El soporte de montaje atornillado directamente en la Unidad de Control puede moverse entre los dos sets de tornillos para alcanzar la posición óptima dentro de la tolva o comedero. Los dos sets de tornillos están aproximadamente a 2” (50mm) de separación.

Hog Slat Inc. Newton Grove, NC USA September 2019 Rev A8 11 Grow-FlexTM Feed System Alambrado: IMPORTANTE Desconectar todas las fuentes de energía antes de atentar la instalación de este (o de cualquier otro equipo),inspeccion o servicio. Conecte a tierra todos los equipos eléctronicos en acuerdo con los códigos aplicables. No asumir que el equipo esta conectado a tierra automáticamente debido al contacto incidental de metal a metal. TODO alambrado eléctronico debe ser realizado por un electricista calificado en acuerdo con los códigos locales y nacionales. El Control de Nivel de Tolva HS529 es de polo sencillo, con interruptor doble que conecta para que el circuito este cerrado normalmente (el Motor Funciona) cuando no hay alimento presente presionando la paleta. El circuito esta abierto (el Motor se Detiene) cuando hay alimento presionando la paleta. El interruptor interno HS529 tiene una capacidad para 20 amperios (Aproximadamente 1HP). Puede ser conectado directamente en series para controlar un motor con menos requerimientos de corriente de 20 amperios. Si la corriente del motor es mayor de 20 amperios, la Unidad de Control debe ser conectada a un relé/contacto. Alambrado para uso con Unidad de Control Grower SELECT HS593 o Unidad de Control CTB 6500 PELIGRO: peligro eléctrico

Hog Slat Inc. Newton Grove, NC USA September 2019 Rev A8 12 Grow-FlexTM Feed System Para aquellas aplicaciones que involucran el uso de Control de Nivel de Tolva HS529 con Controles AP FLX-4496 y FLX-4520; el juego de tuercas y el puente/jumper incluidos deben ser usados para una conexión directa a las unidades AP. Alambrado para uso con AP FLX-4496 o FLX-4520 Interruptor y Pedal de Ajuste: El Control de Tolva se configura en la fabrica para la sensibilidad del Interruptor y la Posición del Pedal para peso y consistencia del alimento average. Es normal que el instalador realice algunos ajustes de afinación basados en el peso real del alimento y su consistencia. Importante: La Tuerca de Ajuste Externa es solo para la posición del pedal. El interruptor de Sencibilidad solo puede ser ajustado internamente. Posición del Pedal 5. Coloque la Unidad de Control en una posición vertital SIN ALIMENTO frente al pedal. 6. Gire la tuerca externa EN DIRECCION DE LAS AGUJAS DEL RELOJ hasta que el interruptor accionador haga (clicks). 7. Gire la tuerca de regreso DIRECCION OPUESTA A LAS AGUJAS DEL RELOJ hasta que el interruptor se desactive (clicks). 8. Gire la tuerca DOS (2) giros completOs adicionales DIRECCION OPUESTA A LAS AGUJAS DEL RELOJ. Ajuste de Interruptor de Sensibilidad: 6. Remover los (4) tornillos y la tapa de la caja de control blanca en la Unidad de Control. 7. Afloje los dos tornillos (2) de ranura #6, tornillos de cabeza hexagonal de arandela que sujetan el soporte del interruptor dentro de la caja blanca. 8. Deslizar interruptor y soporte ensamblado como corresponde:: a. DERECHA para hacer la unidad Menos Sensitiva, require más alimento para accionarse b. IZQUIERDA para hacer la unidad Más Sensitiva, require menos alimento para accionarse. 9. Vuelva a apretar los tornillos (no sobre apretar y estropear) 10. Importante: La posición del pedal debe ser re-ajustada siempre que la sensibilidad del interruptor es ajustada.

Hog Slat Inc. Newton Grove, NC USA September 2019 Rev A8 13 Grow-FlexTM Feed System Lista de Piezas para el Control de Nivel de Tolva HS529 4 Flapper, Shield HS529-7 14 Gasker, Box HS529-49 5 Shield, Rear HS529-8 15 Spring, Adjustment HS529-58 6 Cover, Hopper HS529-9 16 Nut, Nyloc 10-32 SS 1170858 7 Housing, Switch Box HS529-43 17 Switch, Modified EL1052M 8 Bracket, Mount HS529-16 18 Connector Liquid Tight Nylon 1/2' 61646 9 Insulation, Switch HS529-50 19 Pigtail, 10' with Terminals HSPT-005 10 Plunger, 1" HS529-46 20 Bracket, Mounting HS529-19

Hog Slat Inc. Newton Grove, NC USA September 2019 Rev A8 14 Grow-FlexTM Feed System Garantía Limitada Hog Slat El Control de Nivel de Tolva Grower Select está garantizado de estar libre de defectos en materiales o mano de obra durante un periodo de veinticuatro (24) meses a partir de la fecha de compra original del Control. Hog Slat acreditara, reparara o reemplazara a su elección cualquier control considerado defectuoso durante este periodo de tiempo. Los costos laborales asociados a la sustitución o reparación del producto no están cubiertos por el Vendedor/Fabricante. Condiciones y Limitaciones 7. El producto debe ser instalado por y operado de acuerdo con las instrucciones publicadas por el Vendedor/Fabricante o la garantia quedará sin efecto. 8. La garantía se anula si todos los components del Control de Nivel de Tolva no son equipo original suministrado por el Vendedor/Fabricante. 9. Este producto debe ser comprador e instalado por un distribuidor vendedor/autorizado o un representante certificado o la grantía seria anulada. 10. Mal funcionamiento o fallas por mal uso, abuso,negligencia, alteración, accidente o falta de mantenimiento adecuado no se consideran defectos bajo Garantía. 11. Esta Garantía solo se aplica a los componentes / sistemas para el cuidado de aves y ganado. Otras aplicaciones en la industria o el comercio no están cubiertos por esta garantía. 12. Esta Garantía se aplica solamente al Comprador Original del producto. El Vendedor/Fabricante no será responsable por Daño Consecuente o Daño Especial que cualquier comprador pueda sufrir o reclame haber sufrido como resultado de cualquier defecto enel producto. “Consecuencia” o “Daños Especiales” como se usan en este documento incluyen, pero no estan limitados a,perdida o deterioro de productos o mercancías, costos de transporte, perdida de ventas y pedidos, pérdida de ingresos, aumento en gastos generales,mano de obra y gastos incidentales e ineficiencias operativas. ESTA GARANTIA CONSTITUYE LA GARANTIA DEL VENDEDOR/FABRICANTE EN SU COMPLETA Y EXCLUSIVA TOTALIDAD Y ESTE FABRICANTE EXPRESAMENTE RENUNCIA A CUALQUIER OTRA GARANTIA, INCLUYENDO PERO NO LIMITADO A, LAS GARANTIAS EXPRESAS O IMPLICITAS EN CUANTO A COMERCIALIZACION, ADECUADOS CON FINES PARTICULARES DE VENTA Y DESCRIPCIONES O CALIDAD DEL PRODUCTO PROVISTO A CONTINUACION. Los Vendedores/Distribuidores Hog Slat no estan autorizados a modificar o extender los términos y condiciones de esta Garantía en ninguna manera u ofrecer o conceder cualquier otra grantía para los productos Grower Select además de los términos expresamente indicados anteriormente. Un oficial de Hog Slat debe autorizar cualquier excepción a esta garantía por escrito. El Vendedor/Fabricante reserva el derecho a modificar modelos y especificaciones en cualquier momento sin previo aviso ni obligación de mejorar los modelos anteriores. Marzo 2012

Hog Slat Inc. Newton Grove, NC USA September 2019 Rev A8 15 Grow-FlexTM Feed System Esta pagina ha sido intencionalmente dejada en blanco

Hog Slat Inc. Newton Grove, NC USA September 2019 Rev A8 16 Grow-FlexTM Feed System Este equipo debe ser instalado de acuerdo con todos los codigos estatales y locales y regulaciones aplicables que se deben seguir en todos los casos. Las autoridades competentes deben ser consultadas antes que las instalaciones se realicen. Hog Slat, Inc. PO Box 300 Newton Grove, NC 28366 Phone: (910) 594-0219 Fax: (910) 594-1392 www.hogslat.com Copyright © 2012 by Hog Slat, Inc Part Number: HSManual-005 HSART-138 Market: Hog & Poultry

Hog Slat Inc. Newton Grove, NC USA September 2019 Rev A8 17 Grow-FlexTM Feed System Commande de niveau de trémie HS529 Liste de pièces Câblage Installation Remarques générales d’installation : Assurez-vous que l’alimentation électrique est déconnectée du système avant toute intervention. L’installation de cet équipement et de tout équipement de fabricant d’origine connexe doit être réalisée conformément à ces instructions, à celles de l’équipement du fabricant d’origine et aux codes locaux (s’il y a lieu). Le manquement à suivre ces instructions peut causer des dommages à l’équipement et/ou des blessures corporelles ou la mort. Prenez note des étiquettes d’avertissement et de sécurité sur l’équipement et dans les manuels. Portez toujours des vêtements de protection et tout équipement de protection personnelle applicable (lunettes de protection et/ou bouche-oreilles) lors de toute intervention sur l’équipement. Les matériaux, l’équipement et les boîtes à éliminer doivent être recyclés conformément aux codes locaux et nationaux en vigueur À moins d’indication contraire, tous les systèmes de distribution d’aliments pour animaux (diamètres) sont installés de la même manière. Ne raccordez pas de conduit rigide à l’enceinte (boîtier de boîte d’interrupteurs - article 7 de la liste de pièces). Présentation : La commande de niveau de trémie est une commande universelle prévue pour tout système de convoyeur qui transporte de la moulée à écoulement libre. La commande démarre ou arrête automatiquement le système de remplissage à mesure que la pression du niveau de la moulée contre l’assemblage de la palette change. Les commandes peuvent être utilisées dans plus d’une trémie de manière à garantir qu’aucune trémie ne manque de moulée avant que la trémie de l’unité de commande ait besoin de moulée. Dans les applications où plusieurs unités de commande sont utilisées, celles-ci doivent être câblées en parallèle de manière à ce que n’importe quelle unité puisse démarrer le système. La commande HS529 convient aux applications d’élevage de volaille et de porc. Applications d’élevage de volaille La commande de niveau de trémie installée à la fin ou sur la dernière trémie du système de distribution doit être installée à faible hauteur.

Hog Slat Inc. Newton Grove, NC USA September 2019 Rev A8 18 Grow-FlexTM Feed System Applications d’élevage de porc Pour la majorité des installations porcines, la commande de niveau de trémie est installée dans la dernière trémie située à la fin du système de distribution. Installation : La commande de niveau de trémie HS529 doit être installée dans la dernière trémie ou mangeoire située à la fin du système de distribution ou de remplissage. L’unité doit être montée à faible hauteur dans la trémie ou la mangeoire de manière à ce que le niveau de remplissage dans la trémie de commande soit inférieur à celui des autres trémies. Cela entraîne un cycle plus fréquent du système de remplissage pour garantir un niveau de moulée approprié dans chaque trémie ou mangeoire. Cela fournira également un réservoir de moulée dans le système si une autre trémie de commande fait un appel de moulée. Le tuyau de chute de moulée doit être positionné de manière à ce que la moulée soit distribuée au centre et à proximité du sommet de la commande devant la palette. Les tuyaux de chute et les autres unités de commande doivent être positionnés à une hauteur élevée dans les autres trémies ou mangeoires de manière à ce qu’elles se remplissent sans déborder. Important : La commande HS529 doit être montée à la verticale pour garantir le bon mouvement de l’interrupteur et de l’assemblage de la palette. Commande de niveau de trémie HS529 montée à la verticale Déterminez le placement désiré de l’unité de commande et percez deux (2) trous de 7,2 mm (9/32 po) en utilisant le support de montage comme gabarit pour déterminer l’espace entre les trous. Assemblez le support de montage avec les boulons à tête hexagonale 1/4-20 et les contre-écrous du fournisseur. (Pour les applications où il n’existe pas de surface verticale convenable sur la trémie ou la mangeoire, le support de montage doit alors être plié ou formé de manière à s’assurer que l’unité de commande soit complètement à la verticale lorsqu’elle est installée dans le support de montage.) Installez l’unité de commande dans le support de montage. Remarque : Le support de montage boulonné directement à l’unité de commande peut être déplacé entre les deux ensembles de vis pour obtenir un emplacement optimal dans la trémie ou la mangeoire. Les deux ensembles de vis ont une distance d’environ 50 mm (2 po) entre eux.

Hog Slat Inc. Newton Grove, NC USA September 2019 Rev A8 19 Grow-FlexTM Feed System Câblage : IMPORTANT Déconnectez tout équipement électrique avant de tenter d’installer ce dispositif (ou tout équipement), de l’inspecter ou d’effectuer toute intervention d’entretien. Mettez à la masse tout équipement électrique conformément à tous les codes en vigueur. Ne supposez pas que l’équipement sera automatiquement mis à la masse en raison d’un contact de métal à métal accessoire. TOUT câblage électrique doit être installé par un électricien compétent, conformément aux codes électriques locaux et nationaux. La commande de niveau de trémie HS529 est un interrupteur bidirectionnel unipolaire de sorte que le circuit est normalement fermé (le moteur tourne) lorsqu’il n’y a aucune moulée contre la palette. Le circuit est ouvert (le moteur s’arrête) lorsque de la moulée est présente contre la palette. L’interrupteur interne de la commande HS529 a une intensité nominale de 20 A (environ 1 hp). Elle peut être connectée directement en série pour commander un moteur ayant une moins grande exigence de courant que 20 A. Si le courant du moteur est supérieur à 20 A, l’unité de commande doit alors être connectée à un relais/contacteur. Câblage à utiliser avec l’unité de commande GrowerSELECT HS593 ou CTB 6500 DANGER : Décharge électrique

Hog Slat Inc. Newton Grove, NC USA September 2019 Rev A8 20 Grow-FlexTM Feed System Pour les applications impliquant l’utilisation de la commande de niveau de trémie HS529 avec contrôleurs AP FLX-4496 et FLX-4520, La trousse de cavalier et capuchon de connexion incluse doit être utilisée pour une connexion directe aux unités AP. Câblage à utiliser avec le contrôleur AP FLX-4496 ou FLX-4520 Réglage de l’interrupteur et de la palette : La sensibilité de l’interrupteur et la position de la palette de la commande de trémie sont réglées en usine pour une consistance et un poids moyens de moulée. Il est normal que l’installateur ait à effectuer des réglages de précision en fonction de la consistance et du poids réels de la moulée qui sera utilisée. Important : L’écrou de réglage externe ne sert qu’à régler la position de la palette. La sensibilité de l’interrupteur ne peut être réglée qu’intérieurement. Positionnement de la palette 9. Placez l’unité de commande en position verticale, avec AUCUNE MOULÉE devant la palette. 10. Tournez l’écrou externe DANS LE SENS DES AIGUILLES D’UNE MONTRE jusqu’à ce que l’interrupteur s’enclenche (un déclic se fera entendre). 11. Tournez l’écrou DANS LE SENS CONTRAIRE DES AIGUILLES D’UNE MONTRE jusqu’à ce que l’interrupteur se déclenche (un déclic se fera entendre). 12. Tournez l’écrou de DEUX (2) tours supplémentaires complets DANS LE SENS CONTRAIRE DES AIGUILLES D’UNE MONTRE. Réglage de la sensibilité de l’interrupteur : 11. Enlevez les quatre (4) vis et le couvercle du boîtier de commande blanc sur l’unité de commande. 12. Desserrez les deux (2) vis épaulées hexagonales fendues no 6 qui retiennent le support de l’interrupteur à l’intérieur du boîtier blanc. 13. Glissez l’assemblage d’interrupteur et de support : a. À DROITE pour rendre l’unité moins sensible, exigeant plus de moulée pour actionner l’interrupteur. b. À GAUCHE pour rendre l’unité plus sensible, exigeant moins de moulée pour actionner l’interrupteur. 14. Resserrez les vis (sans excès pour ne pas foirer les filets). 15. Important : La position de la palette doit être rajustée chaque fois que la sensibilité de l’interrupteur est de nouveau réglée.

Hog Slat Inc. Newton Grove, NC USA September 2019 Rev A8 21 Grow-FlexTM Feed System Liste de pièces de la commande de niveau de trémie HS529 4 Flapper, Shield HS529-7 14 Gasker, Box HS529-49 5 Shield, Rear HS529-8 15 Spring, Adjustment HS529-58 6 Cover, Hopper HS529-9 16 Nut, Nyloc 10-32 SS 1170858 7 Housing, Switch Box HS529-43 17 Switch, Modified EL1052M 8 Bracket, Mount HS529-16 18 Connector Liquid Tight Nylon 1/2' 61646 9 Insulation, Switch HS529-50 19 Pigtail, 10' with Terminals HSPT-005 10 Plunger, 1" HS529-46 20 Bracket, Mounting HS529-19

Hog Slat Inc. Newton Grove, NC USA September 2019 Rev A8 22 Grow-FlexTM Feed System Garantie limitée Hog Slat La commande de niveau de trémie GrowerSelect est garantie contre tout défaut matériel ou de fabrication pour une période de vingt-quatre (24) mois à compter de la date d’achat d’origine. Hog Slat créditera, réparera ou remplacera, à son choix, toute commande déclarée défectueuse pendant cette période. Les frais de maind’œuvre associés au remplacement ou à la réparation du produit ne sont pas couverts par le vendeur/fabricant. Conditions et restrictions 13.Le produit doit être installé et exploité conformément aux instructions publiées par le vendeur/fabricant, sinon la garantie sera annulée. 14. Tous les composants de la commande de niveau de trémie doivent être des pièces d’équipement d’origine fournies par le vendeur/fabricant pour que la garantie soit valide. 15.Le produit doit être acheté auprès d’un détaillant/distributeur ou d’un représentant certifié de ce dernier, et installé par le détaillant/distributeur ou son représentant. Sinon, la garantie sera annulée. 16.Un mauvais fonctionnement ou une défaillance du produit résultant de la mauvaise utilisation, de l’utilisation abusive, de la négligence, de la modification, d’un accident ou d’un manque d’entretien adéquat ne sera pas considéré comme étant un défaut en vertu de la garantie. 17. Cette garantie ne s’applique qu’aux composants/systèmes pour les soins de la volaille et du bétail d’élevage. Les autres applications dans l’industrie ou le commerce ne sont pas couvertes par cette garantie. 18. Cette garantie ne s’applique qu’à l’acheteur d’origine du produit. Le vendeur/fabricant ne sera pas tenu responsable des dommages immatériels ou dommages-intérêts particuliers que pourrait subir ou déclarer avoir subi un acheteur quelconque en conséquence de tout défaut du produit. Les termes « dommages immatériels » ou « dommages-intérêts particuliers » utilisés aux présentes comprennent, sans toutefois s’y limiter, les produits ou biens perdus ou endommagés, les frais de transport, la perte de ventes, la perte de revenus, l’augmentation des coûts indirects, les frais de main-d’œuvre et accessoires et les inefficiences d’exploitation. CETTE GARANTIE CONSTITUE LA GARANTIE INTÉGRALE ET EXCLUSIVE DU VENDEUR/FABRICANT ET CE FABRICANT NIE EXPRESSÉMENT TOUTE AUTRE GARANTIE, Y COMPRIS, SANS TOUTEFOIS S’Y LIMITER, TOUTE GARANTIE EXPRESSE OU IMPLICITE DE QUALITÉ MARCHANDE, D’ADÉQUATION À UN USAGE PARTICULIER DU PRODUIT VENDU ET DE LA DESCRIPTION OU DE LA QUALITÉ DU PRODUIT FOURNI AUX PRÉSENTES. Les détaillants/distributeurs Hog Slat ne sont pas autorisés à modifier ou proroger les conditions générales de cette garantie de quelque manière que ce soit ou d’accorder toute autre garantie pour les produits GrowerSelect en plus des conditions expressément stipulées plus haut. Un membre de la direction de Hog Slat doit autoriser par écrit toute exception à cette garantie. Le vendeur/fabricant se réserve le droit de modifier les modèles et caractéristiques à n’importe quel moment sans préavis ni obligation d’améliorer les modèles antérieurs. Mars 2012

Hog Slat Inc. Newton Grove, NC USA September 2019 Rev A8 23 Grow-FlexTM Feed System Page laissée vierge intentionnellement

Hog Slat Inc. Newton Grove, NC USA September 2019 Rev A8 24 Grow-FlexTM Feed System Cet équipement doit être installé conformément à tous les codes d’État, provinciaux et locaux, de même qu’aux réglementations applicables qui doivent être respectées en toutes circonstances. Les autorités compétentes doivent être consultées avant de procéder à toute installation. Hog Slat, Inc. PO Box 300 Newton Grove, NC 28366 Téléphone : (910) 594-0219 Télécopieur : (910) 594-1392 www.hogslat.com Copyright © 2012 by Hog Slat, Inc Part Number: HSManual-005 HSART-138 Market: Hog & Poultry

RkJQdWJsaXNoZXIy MTA3MzU=