Hog Slat Inc. Newton Grove, NC USA February 2019 16 Ventilation System F. Remove Drive motor with mounting plate intact. Remove four bolts/nuts that secure motor mounting plate into chassis using 1/2" socket/wrench. G. Slide motor with mounting plate away from the drive screw toward two cutouts found in the chassis approximately 12" from the end of the machine. H. Align mounting bracket with slots and pull motor and plate out of the machine. I. Loosen set-screws in top end flange bearing. J. Remove bolts securing drive screw thrust bearing plate to chassis.