GrowerSELECT - HS583E Enclosed Curtain Machine Service Manual

Hog Slat Inc. Newton Grove, NC USA February 2019 22 Ventilation System I. Remove locking pliers. Grasp limit rod and move it in the opposite direction. Again using locking pliers clamp the limit rod just above the load block to lock the limit rod in position. J. Remove the next cotter pin in line from the bottom (located between motor mount plate and thrust bearing mounting bracket). K. While holding limit rod, remove locking pliers. Limit rod is now loose to be removed from machine. L. Lower limit rod in the direction of the limit switch end approximately 3 inches. Slide the top lock collar off the end of the limit rod. M. Continue to lower limit rod in the direction of the limit switch end of the machine until it is out of the load block. N. Pull limit rod outward and pull up and out of the lower guide holes in the thrust mount plate. O. Remove limit rod from machine noting location of springs, washers and cotter pins. 7.2 Limit Rod Installation A. Install limit rod in reverse order of removal. B. Install new 3/32" x 1" Stainless Steel cotter pins in limit rod at (4) locations. C. If installing new load block assembly, new cotter pins are provided. D. Re-connect power.