GrowerSELECT - HS583E Enclosed Curtain Machine Service Manual

Hog Slat Inc. Newton Grove, NC USA February 2019 25 Ventilation System 9.1 Removal of Limit Switch Enclosure A. Disconnect power B. Remove lower end cap near limit switch enclosure end of machine by removing (4) screws from side of chassis using 5/16" socket/ wrench/drill driver. C. Remove (4) screws from large cover on limit switch enclosure using 5/16" socket/wrench/drill driver. Remove enclosure cover. D. Disconnect incoming wiring from terminal strip (required ONLY if replacement of limit switch enclosure assembly is necessary). E. Loosen set-screw on limit switch slide block using 1/8" Allen wrench. F. Remove (1) bolt and nut holding ground wire to side of chassis located near "OPEN"/"CLOSE" toggle switch. (Not necessary if replacing motor only as the enclosure will only be dropped down out of the way and not removed.)