Hog Slat Inc. Newton Grove, NC USA February 2022 REV A11 7 Ventilation Systems INSTALLATION / OPERATION 1. The HS583E Curtain/Vent machine is equipped with a key hole slot for easy installation as well as (6) locations to secure unit to a wall. 2. Install (1) 3/8” X 3” Lag bolt (supplied) in the wall of the building in the desired location leaving bolt out approximately ¼”. Lag bolt location to be center line of the machine and installed 6 1/4” below the height of the top of the machine. Allow a minimum of 1” clearance above machine from any structure in order to provide adequate clearance for hanging machine on keyhole lag bolt. 3. Hang machine on bolt aligning keyhole slot located near top of the machine. (Figure 1) Figure 1 Keyhole mounting location MODEL LENGTH “A” 24” 30 3/8” 36” 42 3/8” 48” 54 3/8”