GrowerSELECT - HS667-06 Linear Actuator Load Nut Replacement Manual

Hog Slat Inc. Newton Grove, NC USA June 2019 6 Ventilation Systems 12. Using an impact driver, loosen the nut found on the end of the threaded shaft while holding the threaded shaft with tongue and groove pliers to prevent rotation. Use cloth over the shaft to prevent scarring from the holding pliers. Rotate nut CCW to loosen. 13. Once loosened, fully remove nut and plastic spacer. 14. While preventing the threaded shaft from rotating, unscrew (CCW) the load nut from the threaded shaft and remove. 15. Clean the threaded shaft from any foreign debris. Lightly grease the length of the shaft with high quality bearing grease Lithium NLGI Grade 2.