Hog Slat Inc. Newton Grove, NC USA June 2019 8 Ventilation Systems 19. While holding load nut with wrench, tighten output tube to the load nut. Pliers or Phillips screwdriver inserted into the hole at the end of the tube can be used to tighten CW. 20. Clean the output tube with s clean cloth and lightly grease the outside surface of the output tube. 21. Thread load nut/shaft tube onto shaft until the load nut is ¾” FROM THE HOUSING AS SHOWN. THIS SETS THE LOCATION OF THE NUT AT THE FULLY RETRACTED POSITION. 22. Slide outer tube over the output tube.