GrowerSELECT - HS689-3P Feed Line Control Unit Switch 230V Installation Manual
Hog Slat Inc. Newton Grove, NC USA February 2019 1 Grow-Flex™ Feed Systems HS689-3P Feed Line Control Unit Switch Assembly – 230V (3) Phase (Includes Spanish Version - Incluye versión en español) General Installation Notes: Make sure that power is disconnected from system prior to servicing. Installation of this equipment and related OEM equipment should be in accordance with these instructions, OEM’s installation instructions and local codes (if applicable). Failure to follow specified instructions may cause damage to equipment and/or personal injury or death. Take special note of any Warnings or Safety Decals on the equipment and in manuals. Always wear protective clothing and any applicable Personal Protective Equipment (Safety Glasses and/or Ear Plugs) when working with the equipment. Discarded materials, equipment and boxes should be recycled in accordance with local and national codes. Unless otherwise specified, all Feed Delivery Systems (Diameters) are installed similarly. Note: Control Unit Switch Assembly is to be wired in accordance with all applicable local and national electrical wiring codes. All wiring sizes and fuse capacities are to be sized according to applicable electrical code specifications or other regulations. Safety Instructions: Read all safety messages in this manual and on equipment safety decals. Follow recommended precautions and safe operating practices. Ground all electrical equipment for safety. Ground all non-current carrying metal parts to guard against electrical shock. Always keep safety decals in good condition and replace missing or damaged decals. Overview: The HS689-3P Control Unit Switch Assembly is designed for use with a flexible auger feed system where control of an auger drive motor is required. Power to the auger drive motor is done through feed pressure being applied to a diaphragm coupled to an electrical switch internal to the control unit housing. This switch in conjunction with a multi pole relay is used to control the auger drive motor by turning off the power when feed is present and turning on the power when feed has been removed from the control unit housing. Auxiliary switch inputs provide a series circuit that allows the Control Unit Switch Assembly to be controlled by a variety of methods including hopper level, drop tube, proximity and various other control devices found in feed systems. The sensitivity of the electrical switch is not adjustable. ELECTRICAL RATING : 1 ½ HP @ 230VAC MAX, 3 PHASE This device does not provide Thermal Overload Protection. Thermal Overload Protection must be integral to the motor or as separate device. A red indicator light on the side of the switch housing will illuminate when the diaphragm has been pressed (MOTOR OFF) and the switch has been activated. The ON/OFF switch is used to enable or disable the Control Unit. DO NOT USE THIS SWITCH AS DISCONNECTING MEANS FOR SERVICING.
Made with FlippingBook
RkJQdWJsaXNoZXIy MTA3MzU=