Hog Slat Inc. Newton Grove, NC USA MAY 2023 REV IR 2 Grow-Flex™ Feed Systems A red indicator light on the side of the switch housing will illuminate when the diaphragm has been pressed (MOTOR OFF) and the switch has been activated. The ON/OFF switch is used to enable or disable the Control Unit. DO NOT USE THIS SWITCH AS DISCONNECTING MEANS FOR SERVICING. HS693T Feed Line Control Unit Parts List of serviceable components REF # PART # DESCRIPTION REF # PART # DESCRIPTION 1 HS590-1 ASSEMBLY HOPPER (used on HS693) 12 HSLABEL-008 WARNING- SHOCK HAZARD DECAL 1 HS703-1 ASSEMBLY HOPPER (used on HS693-108) 13 HS589-2 COVER, SWITCH HOUSING 2 HS590-11 ACCESS GATE 14 EL1161 Terminal Strip 8 Position 10 AWG Max 3 HS591 DROP CONE - CLARIFIED PLASTIC 15 HS689-6 BRACKET, TERMINAL MOUNT OFFSET 4 HS582 DIAPHRAGM ASSEMBLY 16 EL1052M SNAP ACTION 20A @ 250VAC SWITCH 5 HS529-45 PLUNGER SEAL 17 HS589-5 SWITCH MOUNT 6 HS589-1 BOX, SWITCH HOUSING 18 EL1079 INDICATOR LAMP, RED, 250 VAC 7 HS589-4 COMPONENT MOUNT PLATE 19 EL1011 SWITCH, TOGGLE DPST, 20A @ 250V, 1 ½ HP 8 EL1081 RELAY BRACKET 20 EL1083 TOGGLE SWITCH BOOT COVER 9 EL1080 RELAY, MULTIPOLE, NO 208-240V, 25A 21 EL1082 LEGEND PLATE 10 HS589-3 GASKET 22 HS589-6 SWITCH PIN 11 60932 Screw #10-16 x 1-1/4" SS 23 HS590-21 PLATE, ADAPTER, HOPPER (used on HS693-108) 24 HS589-8 PLATE ASSEMBLY MOUNT CONTROL BOX 25 EL1088 TIME DELAY, 1 – 100 SECONDS HS689T - Control Unit Switch Assembly 230V-Single Phase With Relay Safety Decal HSLABEL-035 “Warning Rotating Auger”
RkJQdWJsaXNoZXIy MTA3MzU=