Hog Slat Inc. Newton Grove, NC USA MAY 2023 REV IR 4 Grow-Flex™ Feed Systems FACTORY WIRING DIAGRAM FIGURE 2 Adjusting Time Delay: The internal time delay is an ON delay. It is factory adjusted to approximately 30 seconds however this can be adjusted up to 100 seconds. Remove front cover from the HS689T and locate timer. Adjust the time dial to desired delay. Rotate clockwise to increase time delay. Each tick mark represents approximately 10 seconds. When troubleshooting a system it may be necessary to adjust the time delay to the minimum setting in order for the auger motor to come on with minimal delay. Once troubleshooting is complete, ALWAYS INCREASE DELAY TO DESIRED SETTING. It is recommended not to operate below 30 seconds to prevent short cycling of feed system motor. Note: When using drop tube switch controls that also have time delay, the delays will add together so it may be necessary to adjust drop tube switch and/or the HS689T control unit switch to obtain the total desired delay. 1 TO 100 SECONDS EACH TICK MARK IS APPROX. 10 S