GrowerSELECT - HS9005 Fan Motor Replacement Installation Manual

Hog Slat Inc. Newton Grove, NC USA February 2019 Fan Motor Replacement Installation Method 3: Replacement of an Existing motor mounted using the four (4) mounting studs on face of motor. In this application, the Ridged Base interferes with Fan Struts and New Motor base must be altered. (Some Aerotech applications) Existing Motor with Stud Mount Nut (4 total) Save for new motor Fan Strut New Motor Modify motor as shown below CUT LINES CUT LINES Step 1 Use tin snips or hack saw to remove front corner of rigid base Step 2 After making cuts motor should look like this Fan Strut Nut Step 3 Motor can now be mounted in fan. Rigid base should clear fan struts . Step 4 Tighten nuts securely Installation is Complete HSART-007 Rev A2 Market: Hog & Poultry Trl: aw

RkJQdWJsaXNoZXIy MTA3MzU=