Hog Slat Inc. Newton Grove, NC USA February 2022 4 Evaporative Cooling System Installation Information Before beginning installation turn off water supply and discount pump from power! 1. Open lid to HSCC-5000 and wire HSCC-5001 to the terminal block shown below. The wire should pass through the small liquid tight. Red wire should be located on left terminal and black wire on right terminal as shown below. Ensure the liquid tight is properly sealed around signal wire. 2. Adjust the OPEN TIME to the setting determined earlier. 3. Adjust the DAYS setting ONLF IF THE pH EVALUATION WAS COMPLETED! 4. Install Batteries supplied with kit. 5. While the sun is up test the unit by pressing and releasing the test button. If the photocell is working properly the photo led will illuminate. If the valve is installed and working properly the valve will open and the out led will illuminate. The valve will return to the closed position after a few seconds. IF THE UNITS FAILS TO OPERATE INSPECT CONNNECTIONS OF PHOTOCELL, HSCC5001 AND ALSO CHECK FOR PROPER BATTERY INSTALLATION. 6. Re-install lid and tighten screws