Hog Slat Inc. Newton Grove, NC USA May 2020 REV A8 6 GROW-DISK™ Feed System 5. MOUNTING CONTROLLER ON THE WALL: It is recommended to mount the controller on an interior wall in the service area. The touchscreen should be at eye level. The enclosure measures approximately 12” x 9” x 5” deep. It is recommended to leave a 6” gap on each side of the controller. Open controller front cover by loosening the two screws found on the left side of the cover. Mount controller using (4) #6 screws or equivalent through the four corners as shown. Do not over-tighten as damage to enclosure could occur. 6. ELECTRICAL CONNECTIONS: Warning! All wiring must be done by a certified electrician according to national and local wiring codes. The controller must be permanently connected. Disconnect power before opening the enclosure. All wiring must enter from the BOTTOM of the enclosure. You must NOT drill any holes on the side or the top of the enclosure. Doing so may allow water to enter into the enclosure and cause electrical damage to circuits. Connect conduit through provided holes in bottom of enclosure. Remove liquid tight plugs to gain access. Use the recommended fuse sizes with the appropriate agency approvals. Do NOT use fuses with a higher amp capacity as this will void the warranty and reduce the lifetime of the system. If a load is too high and blows the fuse regularly, use an external contactor with appropriate rating for the load.