Hog Slat Inc. Newton Grove, NC USA May 2020 REV A8 8 GROW-DISK™ Feed System CONNECTING MAINS SUPPLY AND CHAIN DISK MOTOR: SINGLE PHASE 220/240V, 50/60Hz The Toggle witch does NOT cut the power to the chain disk controller or Chain disk controller or the drive system. Disconnect power before servicing. CONNECTIONS: All connected wire shall be “COPPER CONDUCTORS ONLY” Mains Supply (L1/L2 Power In) and Chain Disk motor – 12 to 4 AWG wire size. Recommended tightening torque 40 in-lb. Circuit breaker – 20A max. Auger Motor shall be on separate breaker. Circuit breaker – 15 A max. 14 to12 AWG wire size. Toggle, Proximity, Chain disk safety and security switches shall be 14 AWG, max length of 300 ft [90M]. Actuator, Alarm and Trouble Light outputs shall be 14 AWG, maximum length of 300ft [90M]