GrowerSELECT HSES Evaporative Cooling System Installation Manual

Hog Slat Inc. Newton Grove, NC USA March 2022 22 Evaporative Cooling System 5. Using Supplied PVC cement and PVC cleaner build the Intake assembly as shown below in Figure 25. Ensure that intake holes are oriented towards the bottom of trough and that the intake pipe is parallel to the bottom of the trough. To ensure pump water supply is not interrupted pick up pipe should be installed a minimum of 2 feet away from incoming water supply! Figure 25 Please note: 115 Volt pump installation may require a variation in installation. • Pumps should be able to be removed from the system completely for winterization. • If required, install 1 ½” Union (603841) between 45 degree elbow and 90 degree elbow and the pump union (H2P-003) is replaced with a 1 ½” Male adapter. • The required components are included in the corresponding pump kits.