GrowerSELECT HSES Evaporative Cooling System Installation Manual

Hog Slat Inc. Newton Grove, NC USA March 2022 26 Evaporative Cooling System SUBMERSIBLE PUMP END FEED Tank Installation (Center Feed) The center feed kit is an additional installation option and requires a separate order of part number HSES-45. 1. Select and mark the center of the trough where 4” bulk head (HSES-45) will insert. Drill a 4” hole in center of trough allowing room for lock nut of the tank adapter to fit. Insert the threaded end of the tank adapter with one rubber gasket on the exterior and one on the interior of the trough. Securely tighten lock nut inside trough. • HOLE SHOULD LEAVE A MINIMUM OF 2.75” FROM THE BOTTOM OF THE TROUGH • A SMALL SECTION OF THE TROUGH COVER DIRECTLY OVER THE 4” TANK ADAPTER MAY HAVE TO BE REMOVED TO ALLOW TROUGH COVER TO SIT LEVEL ONTO TROUGH 2. Connect the Tank (HSES-40) to the bulkhead using the supplied flexible hose (HSES-39). 5 feet of hose is supplied with each system. If additional hose is required please order separate. Using all (4) hose clamps (620-072) secure hose to the bulk head and to the entry of the Tank as shown below in Figure 30. Figure 30

RkJQdWJsaXNoZXIy MTA3MzU=