GrowerSELECT - HSIN3000C Actuated Two Door Ceiling Inlet Installation Manual

Hog Slat Inc. Newton Grove, NC USA March 2018 13 Ventilation Systems Step 8: Remove the two pieces of 1/8 inch diameter rope (62040-1000) and the cable clamp (617321) from the hardware bag included with the inlet. Open the inlet doors if they are not already open. Secure the two pieces of rope to the steel rod with the clamp. The clamp should be located 1-3 inches away from the eye bolt furthest away from the actuator. Pull the two pieces of rope through the eye bolt. Step 9: Pull each piece of rope through the blue loop of the latch mount and cable guide (HSI1-3), slide it through the center hole in the inlet doors, and secure it tightly in the side entry cleat (HSI1-7). Figures 15 and 16 are shown with the inlet door closed for clarity. Rope Connection to Rod (Figure 14) Side Entry Cleat (Figure 16) Rope through Blue Loop (Figure 15) NOTE: There are two eyebolts so that the inlet can be oriented in either direction when attached to the ceiling.