Hog Slat Inc. Newton Grove, NC USA October 2019 10 Ventilation Systems Connection to Actuation System Selecting an Actuation System: Either the GrowerSELECT curtain machine (HS583E) or the linear actuator (HS667-24) can be used to actuate the inlet system in conjunction with a winch. Actuation Force Required*: Force (lbsf) Static Pressure (inH2O) 0.00 0.05 0.10 0.15 0.20 HSIN1700SW 3.03 3.56 4.08 4.60 5.12 HSIN3050SW 5.10 5.88 6.67 7.45 8.23 Force (kg) Static Pressure (Pa) 0 10 20 30 40 HSIN1700SW 1.4 1.6 1.9 2.0 2.3 HSIN3050SW 2.3 2.7 3.0 3.4 3.8 *Actuation force may vary depending on setup and other local conditions. HS667-24 Linear Actuator (Figure 16) Max Load: 772 lbs Max Speed: 1/4” per second Stroke Length: 24” HS583E Curtain Machine (Figure 15) Max Load: 2,000 lbs Max Speed: 15 RPM Length: 24” Note: The rating is based on HS583E-2415. Other models can be used and will have a different rating.
RkJQdWJsaXNoZXIy MTA3MzU=