GrowerSelect - AirStorm 24 Inch Poly Panel Fan Instruction Manual

Hog Slat Inc. Newton Grove, NC USA July 2023 1 Air Storm Fans AS-24CPV Fan Circ. 24" Poly Panel 1140RPM 115/230 60Hz Var Speed

Hog Slat Inc. Newton Grove, NC USA July 2023 2 Air Storm Fans Table of Contents Grower SELECT General Page ................................................................................................................................3 Safety .........................................................................................................................................................................4 Warning Labels .......................................................................................................................................................4 Installation ...............................................................................................................................................................5 Operation Safety .....................................................................................................................................................5 Maintenance Safety ................................................................................................................................................5 Dimensions ...............................................................................................................................................................6 Installation .................................................................................................................................................................7 Wiring and Electrical Installation ......................................................................................................................... 10 Pre-Operation Assessment .................................................................................................................................. 11 Operation ................................................................................................................................................................ 11 Maintenance ........................................................................................................................................................... 11 Troubleshooting .................................................................................................................................................... 12 Performance ........................................................................................................................................................... 12 Exploded Diagrams/Replacement Parts ............................................................................................................. 13 Hog Slat Limited Warranty.................................................................................................................................... 15

Hog Slat Inc. Newton Grove, NC USA July 2023 3 Air Storm Fans Grower SELECT General Page General Installation Notes: Make sure that power is disconnected from system prior to servicing. Installation of this equipment and related OEM equipment should be in accordance with these instructions, OEM’s installation instructions and local codes (if applicable). Failure to follow specified instructions may cause damage to equipment and/or personal injury or death. Take special note of any Warnings or Safety Decals on the equipment and in manuals. Always wear protective clothing and any applicable Personal Protective Equipment (Safety Glasses and/or Ear Plugs) when working with the equipment. Discarded materials, equipment and boxes should be recycled in accordance with local and national codes. Safety Instructions: Read all safety messages in this manual and on equipment safety decals. Follow recommended precautions and safe operating practices. Ground all electrical equipment for safety. Ground all non-current carrying metal parts to guard against electrical shock. Always keep safety decals in good condition and replace missing or damaged decals.

Hog Slat Inc. Newton Grove, NC USA July 2023 4 Air Storm Fans Safety Warning Labels Warning Decals have been placed on the equipment to warn of potentially dangerous situations. Care should be taken to keep this information intact and easy to read at all times. Replace missing or damaged safety signs. Safety–Alert Symbol This is a safety–alert symbol. When you see this symbol on your equipment, be alert to the potential for personal injury. GrowerSelect equipment is designed to be installed and operated as safely as possible...however, hazards do exist. Safety decals should be read and understood thoroughly by individuals within the local area of the fan. Safety decals should be visible from both the front and back of the fan. Should a decal be missing or damaged, please contact Hog Slat Inc. for a free replacement: Hog Slat Inc. 206 Fayetteville St. Newton Grove, NC 28366 Toll Free: 800-949-4647 Local: 910-594-0219 The below safety decal should be represented and visible on both the front and back sides of the fan. This label is identified by the HSLABEL-080 part number in the lower right corner. WARNING – FLYING OBJECTS AND ROTATING PARTS Ensure fan guards are in place during operation. Securely tighten propeller to shaft to avoid slipping. Disconnect power supply for inspection or service when guards are removed and personnel are exposed to propeller. WARNING – HIGH VOLTAGE Disconnect electrical power before inspecting or servicing equipment unless maintenance instructions specifically states otherwise. Ground all electrical equipment for safety. All electrical wiring must be done by a qualified electrician in accordance with local and national electrical codes. Ground all non-current carrying metal parts to guard against electrical shock. With the exception of motor overload protection, electrical disconnects and over current protection are not supplied with the equipment.

Hog Slat Inc. Newton Grove, NC USA July 2023 5 Air Storm Fans Installation Prior to any installation product should be inspected for any damage caused during shipping. Any damage found should be documented and communicated to liable parties. Operation Safety When fan is in operation no attempt should be made to service or interact with parts from the fan. Any attempt to interact with fan parts while the fan is operating could result in injury. Inlet and exit guards and or shutters are in place to help prevent foreign objects from entering inside the outer perimeter of the housing. If maintenance to the fan is required, interrupt the source of power to the motor and allow propeller to come to a complete stop before moving forward with any efforts to service. Maintenance Safety Wind Storm Fans are designed and built with operator safety in mind. Some safeguards must be disassembled or removed for the parts to be serviced or replaced. As this fan does have moving parts and is supplied with electrical power, steps must be taken to ensure safety around these presented hazards. READ THESE INSTRUCTIONS BEFORE SERVICE OR PART REPLACEMENT 1. Read and understand the operating manual before trying to install or operate Wind Storm Fans. 2. Power supply should be turned OFF and LOCKED OUT for service to motor and electrical components. Use CAUTION in checking voltage or other procedures requiring power to be ON. 3. DO NOT attempt to bypass any safety features or devices to operate the fan. 4. Keep fan clean of all debris that may collect on the motor, prop, and any bearings, belts, or pulleys. 5. Use CAUTION in working around all moving parts of the fan. Fan guards or shutters must be in place before fan can be safely started and operational.

Hog Slat Inc. Newton Grove, NC USA July 2023 6 Air Storm Fans Dimensions

Hog Slat Inc. Newton Grove, NC USA July 2023 7 Air Storm Fans Installation The following guide lines should be followed regardless of installation method. Any deviation from these parameters will void the warranty. 1. The capacitor housing on the motor should always be oriented upward towards the ceiling and the hooks should be secured in the mounting holes. 2. Fan tilt can be set by moving hooks to different holes in the hanging bracket.

Hog Slat Inc. Newton Grove, NC USA July 2023 8 Air Storm Fans 3. If more fan tilt is required a third chain can be attached at the bottom bracket. The fan cannot be tilted more than 50°. 4. The fan operating area must be clear of obstructions for a 4 foot diameter extending around the fan from the blade.

Hog Slat Inc. Newton Grove, NC USA July 2023 9 Air Storm Fans 5. The drain tabs on the mounting side of the motor must be removed prior to operation. The drain tabs on the capacitor side of the motor MUST NOT BE REMOVED UNDER ANY CIRCUMSTANCE. WALL MOUNT Wall mounting requires a wall framed with 6” dimensional lumber and a 32” x 32” rough opening 1. Align fan with rough opening with the motors capacitors facing upwards. 2. Secure fan with lags screws

Hog Slat Inc. Newton Grove, NC USA July 2023 10 Air Storm Fans 3. Remove hardware from guard and slip cone over outside of housing. Reinstall guard hardware. 4. Install shutter hardware, Wiring and Electrical Installation General Installation Notes: Make sure that power is disconnected from system prior to servicing. Installation of this equipment and related OEM equipment should be in accordance with these instructions, OEM’s installation instructions and local codes (if applicable). Failure to follow specified instructions may cause damage to equipment and/or personal injury or death. Take special note of any Warnings or Safety Decals on the equipment and in manuals.

Hog Slat Inc. Newton Grove, NC USA July 2023 11 Air Storm Fans Always wear protective clothing and any applicable Personal Protective Equipment (Safety Glasses and/or Ear Plugs) when working with the equipment. Discarded materials, equipment and boxes should be recycled in accordance with local and national codes. Safety Instructions: Read all safety messages in this manual and on equipment safety decals. Follow recommended precautions and safe operating practices. Ground all electrical equipment for safety. Ground all non-current carrying metal parts to guard against electrical shock. ! WARNING ! Installation, operation, and maintenance must be performed by qualified personnel. All work should adhere strictly to the National Electrical Code and National Fire Protection Association standards. Pre-Operation Assessment Before beginning fan operation, please follow the below checklist to ensure that:  Fan power cord securely connected to a good power supply.  All safety labels are visible to personnel that will work in the area.  Exit wire guard and inlet shutter are in place and secured to the fan housing.  No foreign objects are protruding through the fan housing. Operation At all times during operation, fan orifice should be free of debris. In the event any component of the fan is compromised, discontinue use immediately and contact your local Hog Slat representative. Maintenance In order to begin any maintenance or service to the fan, power must be turned OFF and all moving parts must come to a complete STOP before accessing. All parts inside of the fan housing are accessed by removing the exit wire guard and inlet shutter. Once service is complete, clean excessive build-up from parts. Excessive dust and dirt on parts can cause vibration in the propeller and overheating of the motor. Before beginning operation again, ensure that all safeguards are back in place and all foreign objects are free from the area. DURING MAINTENANCE AND OPERATION THE FOLLOWING MUST BE MAINTAINED TO ENSURE PROPER PERFORMANCE AND TO EXTEND USABLE COMPONENT LIFE.

Hog Slat Inc. Newton Grove, NC USA July 2023 12 Air Storm Fans Troubleshooting Trouble Possible Cause(s) Corrective Action Excessive noise Worn motor bearing. Replace Damage to fan blade Replace prop Loose fasteners on motor or housing Tighten fasteners Excessive vibration Fan blade is out of balance due to dirt build-up. Clean entire unit Fan blade is out of balance due to damage Replace prop Insufficient airflow Intake or exhaust guards clogged with debris Clean entire unit Intake or exhaust blocked by foreign object Remove object from airflow path Fan won’t operate Open power supply circuit. Check wiring and reset circuit breaker Defective motor Reset motor, repair, or replace Motor overheats and nuisance trips Improper airflow due to clogged Inlet/Outlet Clean entire unit Motor or Fan prop has excessive debris build-up Clean entire unit Performance Hog Slat Inc. takes great pride in supplying our customers with fans that meet or exceed their performance numbers. This is achieved by testing fans from the production line and continually working to maintain consistency in test data. AS-24CPV HSSFT-0158 5/31/2023 D impeller (in.) Thrust (lbf) Thrust Efficiency Ratio (lbf/kW) rpms Volts Amps kW Airflow* (thrust cfm) Efficiency (thrust cfm/W) 24.9 8.4 14.7 1125 232.8 2.72 0.573 6500 11.3 5D Centerline Velocity (fpm) = 1300

Hog Slat Inc. Newton Grove, NC USA July 2023 13 Air Storm Fans HSPCT-01241 static pressure (in H2O) volumetric airflow (cfm) airflow efficiency (cfm/WATT) Volts Amps WATTS RPM 0.000 7104 13.2 230.2 2.59 539 1115 -0.025 6961 12.7 230.1 2.63 547 1113 -0.050 6809 12.3 230.0 2.66 554 1111 -0.075 6649 11.9 230.0 2.70 562 1110 -0.100 6480 11.4 229.9 2.73 569 1108 -0.125 6301 10.9 229.9 2.77 576 1106 -0.150 6110 10.5 229.8 2.80 584 1104 -0.175 5909 10.0 229.7 2.84 591 1103 -0.200 5694 9.5 229.7 2.87 599 1101 HSPCT-01240 static pressure (in H2O) volumetric airflow (cfm) airflow efficiency (cfm/WATT) Volts Amps WATTS RPM 0.000 6608 11.3 230.3 2.77 585 1111 -0.025 6453 11.0 230.3 2.80 588 1109 -0.050 6303 10.7 230.4 2.82 591 1108 -0.075 6154 10.3 230.5 2.85 594 1106 -0.100 5999 10.0 230.5 2.87 598 1105 -0.125 5836 9.7 230.6 2.89 601 1103 -0.150 5660 9.4 230.6 2.92 604 1102 -0.175 5466 9.0 230.7 2.94 607 1100 -0.200 5251 8.7 230.8 2.97 610 1099 Exploded Diagrams/Replacement Parts

Hog Slat Inc. Newton Grove, NC USA July 2023 14 Air Storm Fans AS-24CPV Item Key Replacement Part Number Description 1 AS-24309 Venturi 24" Poly Panel Black 2 AS-24119B Mount Guard Interior 24" Panel 3 HS9088C Motor 1/2 HP 1125 RPM 115/208-230V 60/50 Hz 48 Fr Var 4 HS900-24A Prop 24" Fiberglass (requires HS903-1 transtorque) 5 AS902-24EC Guard Fan 24" Air Storm 7 HS903-1 Nut Transtorque 1/2" W/7/8" Hex Nut Keyless Bushing 14 AS-24115 Bracket Hanging AS-24PDD/AS-24PDDO

Hog Slat Inc. Newton Grove, NC USA July 2023 15 Air Storm Fans Hog Slat Limited Warranty Hog Slat warrants products to be free from defects in material or workmanship for a period of twenty-four (24) months from the date of original purchase. Hog Slat will credit, repair, or replace, at its option any product deemed defective within this time period. Labor costs associated with the replacement or repair of the product are not covered by the Seller/Manufacturer. Conditions and Limitations 1. The product must be installed by and operated in accordance with the instructions published by the Seller/Manufacturer or Warranty will be void. 2. Warranty is void if all components are not original equipment supplied by the Seller/Manufacturer. 3. This product must be purchased from and installed by an authorized retailer/distributor or certified representative thereof or the Warranty will be void. 4. Malfunctions or failure resulting from misuse, abuse, negligence, alteration, accident, or lack of proper maintenance shall not be considered defects under the Warranty. 5. This Warranty applies only to components/systems for the care of poultry and livestock. Other applications in industry or commerce are not covered by this Warranty. 6. This Warranty applies only to the Original Purchaser of the product. The Seller/Manufacturer shall not be liable for any Consequential or Special Damage which any purchaser may suffer or claim to suffer as a result of any defect in the product. “Consequential” or “Special Damages” as used herein include, but are not limited to, lost or damaged products or goods, costs of transportation, lost sales, lost orders, lost income, increased overhead, labor and incidental costs and operational inefficiencies. THIS WARRANTY CONSTITUTES THE SELLER/MANUFACTURER’S ENTIRE AND SOLE WARRANTY AND THIS MANUFACTURER EXPRESSLY DISCLAIMS ANY AND ALL OTHER WARRANTIES, INCLUDING, BUT NOT LIMITED TO, EXPRESS AND IMPLIED WARRANTIES AS TO MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSES SOLD AND DESCRIPTION OR QUALITY OF THE PRODUCT FURNISHED HEREUNDER. Hog Slat Retailers/Distributors are not authorized to modify or extend the terms and conditions of this Warranty in any manner or to offer or grant any other warranties for GrowerSelect products in addition to those terms expressly stated above. An officer of Hog Slat must authorize any exceptions to this Warranty in writing. The Seller/Manufacturer reserves the right to change models and specifications at any time without notice or obligation to improve previous models.

Hog Slat Inc. Newton Grove, NC USA July 2023 16 Air Storm Fans This equipment must be installed in accordance with all State and Local Codes and applicable Regulations which should be followed in all cases. Authorities having jurisdiction should be consulted before installations are made. Hog Slat, Inc. PO Box 300 Newton Grove, NC 28366 Phone: (910) 594-0219 Fax: (910) 594-1392 www.hogslat.com Copyright © 2023 by Hog Slat, Inc. Part Number: HSManual-176 Rev IR HSART-554 Market: Hog & Poultry