Hog Slat Inc. Newton Grove, NC USA May 2023 42 Poultry Feed Systems Problem Possible Cause Corrective Action Motor runs, but auger does not turn. Sheared driver bolt at Control Unit. Replace driver bolt. Broken power unit pinion. Examine pinion on motor shaft; replace BOTH gear head and pinion if pinion is damaged. Auger wears holes in tubes. Auger kinked or poorly brazed. See Auger Brazing section in this manual Elbows wear out. Auger is stretched too tight; horizontal L.H. turn; auger has been running dry. Lengthen auger; Install an Extension Hopper. Excessive auger vibration and noise. System has been operated too often without feed (auger has scored the auger tubes). Replace damaged auger tubes; be sure auger has proper amount of stretch. Tubes inadequately supported. Support the tubes every 5’ (1.5 m) or closer. Horizontal L.H. turn. No outlet drops on or just before an elbow; lengthen the auger; install an Extension Hopper ahead of elbows. Fill system short cycles. Control end feed level switch does not provide large enough feed differential. Use a time clock to program operating cycles. Use Control end feed level switch w/lockout and time clock.