Hog Slat Inc. Newton Grove, NC USA November 2021 Wind Storm Fans WS-36411 Shutter Kit Installation Manual
Hog Slat Inc. Newton Grove, NC USA November 2021 2 Wind Storm Fans Table of Contents GrowerSELECT General Page........................................................................................................................... 3 Safety ................................................................................................................................................................. 4 Warning Labels ................................................................................................................................................ 4 Installation........................................................................................................................................................ 5 Operation Safety .............................................................................................................................................. 5 Maintenance Safety.......................................................................................................................................... 5 Installation ......................................................................................................................................................... 6 Brackets........................................................................................................................................................... 6 Pre-Operation Assessment............................................................................................................................... 7 Maintenance....................................................................................................................................................... 8 Exploded Diagrams ........................................................................................................................................... 9
Hog Slat Inc. Newton Grove, NC USA November 2021 3 Wind Storm Fans GrowerSELECT General Page General Installation Notes: Make sure that power is disconnected from system prior to servicing. Installation of this equipment and related OEM equipment should be in accordance with these instructions, OEM’s installation instructions and local codes (if applicable). Failure to follow specified instructions may cause damage to equipment and/or personal injury or death. Take special note of any Warnings or Safety Decals on the equipment and in manuals. Always wear protective clothing and any applicable Personal Protective Equipment (Safety Glasses and/or Ear Plugs) when working with the equipment. Discarded materials, equipment and boxes should be recycled in accordance with local and national codes. Safety Instructions: Read all safety messages in this manual and on equipment safety decals. Follow recommended precautions and safe operating practices. Ground all electrical equipment for safety. Ground all non-current carrying metal parts to guard against electrical shock. Always keep safety decals in good condition and replace missing or damaged decals.
Hog Slat Inc. Newton Grove, NC USA November 2021 4 Wind Storm Fans Safety Warning Labels Warning Decals have been placed on the equipment to warn of potentially dangerous situations. Care should be taken to keep this information intact and easy to read at all times. Replace missing or damaged safety signs. Safety–Alert Symbol This is a safety–alert symbol. When you see this symbol on your equipment, be alert to the potential for personal injury. GrowerSelect equipment is designed to be installed and operated as safely as possible...however, hazards do exist. Safety decals should be read and understood thoroughly by individuals within the local area of the fan. Safety decals should be visible from both the front and back of the fan. Should a decal be missing or damaged, please contact Hog Slat Inc. for a free replacement: Hog Slat Inc. 206 Fayetteville St. Newton Grove, NC 28366 Toll Free: 800-949-4647 Local: 910-594-0219 The below safety decal should be represented and visible on both the front and back sides of the fan. This label is identified by the HSLABEL-080 part number in the lower right corner. WARNING – FLYING OBJECTS AND ROTATING PARTS Ensure fan guards are in place during operation. Securely tighten propeller to shaft to avoid slipping. Disconnect power supply for inspection or service when guards are removed and personnel are exposed to propeller. Figure 1: HSLABEL-080 Warning Label WARNING – HIGH VOLTAGE Disconnect electrical power before inspecting or servicing equipment unless maintenance instructions specifically states otherwise. Ground all electrical equipment for safety. All electrical wiring must be done by a qualified electrician in accordance with local and national electrical codes. Ground all non-current carrying metal parts to guard against electrical shock. With the exception of motor overload protection, electrical disconnects and over current protection are not supplied with the equipment.
Hog Slat Inc. Newton Grove, NC USA November 2021 5 Wind Storm Fans Installation Prior to any installation, product should be inspected for any damage caused during shipping. Operation of a damaged fan could cause injury and further damage to the fan. Any damage found should be documented and communicated to liable parties. Operation Safety When the fan is in operation, no attempt should be made to service or interact with parts from the fan. Any attempt to interact with fan parts while the fan is operating could result in injury. Front and rear wire guards are in place to help prevent foreign objects from entering inside the outer perimeter of the housing. If maintenance to the fan is required, interrupt the source of power to the motor and allow propeller to stop spinning completely before moving forward with any efforts to service. Maintenance Safety Wind Storm Fans are designed and built with operator safety in mind. Some safeguards must be disassembled or removed for the parts to be serviced or replaced. As this fan does have moving parts and is supplied with electrical power, steps must be taken to ensure safety around these presented hazards. READ THESE INSTRUCTIONS BEFORE SERVICE OR PART REPLACEMENT 1. Read and understand the operating manual before trying to install or operate Wind Storm Fans. 2. Power supply should be turned OFF and LOCKED OUT for service to motor and electrical components. Use CAUTION in checking voltage or other procedures requiring power to be ON. 3. DO NOT attempt to bypass any safety features or devices to operate the fan. 4. Keep fan clean of all debris that may collect the motor, prop, and any bearings, belts, or pulleys. 5. Use CAUTION in working around all moving parts of the fan. Fan guards or shutters must be in place before fan can be safely started and operational.
Hog Slat Inc. Newton Grove, NC USA November 2021 6 Wind Storm Fans Installation IMPORTANT NOTE: THIS FAN SHOULD NOT BE INSTALLED IN A STATIC PRESSURE APPLICATION. Brackets Orient brackets (WS-36410) as shown in the image below and fasten with (5) 6088612 sheet metal screws. If the fan panels don’t have a pre-drilled hole then drill a 3/16” hole for each screw using the WS-36410 bracket as a template leaving a 1/2” gap to slide the shutter into. Figure 2: WS-36410 Bracket Installation
Hog Slat Inc. Newton Grove, NC USA November 2021 7 Wind Storm Fans Shutter Slide the shutter (101200) into the pocket created by the brackets as shown below. Figure 3: 101200 Shutter Installation Pre-Operation Assessment Before beginning fan operation, please follow the below checklist to ensure that: Fan power cord securely connected to a good power supply. All safety labels are visible to personnel that will work in the area. Front and back wire guards are in place and secured to the fan housing. No foreign objects are protruding though the fan housing.
Hog Slat Inc. Newton Grove, NC USA November 2021 8 Wind Storm Fans Maintenance In order to begin any maintenance or service to the fan, power must be turned OFF and all moving parts must come to a complete STOP before accessing. All parts inside of the fan housing are accessed by removing the front and rear wire guard panels. Once service is complete, clean excessive build-up from parts. Excessive dust and dirt on parts can cause vibration in the propeller and overheating of the motor. Before beginning operation again, ensure that all safeguards are back in place and all foreign objects are free from the area.
Hog Slat Inc. Newton Grove, NC USA November 2021 9 Wind Storm Fans Exploded Diagrams Figure 3: WS-36411 Exploded View
Hog Slat Inc. Newton Grove, NC USA November 2021 10 Wind Storm Fans This Page Intentionally Left Blank
Hog Slat Inc. Newton Grove, NC USA November 2021 11 Wind Storm Fans
Hog Slat Inc. Newton Grove, NC USA November 2021 12 Wind Storm Fans This equipment must be installed in accordance with all State and Local Codes and applicable Regulations which should be followed in all cases. Authorities having jurisdiction should be consulted before installations are made. Hog Slat, Inc. PO Box 300 Newton Grove, NC 28366 Phone: (910) 594-0219 Fax: (910) 594-1392 www.hogslat.com Copyright © 2018 by Hog Slat, Inc. Part Number: HSMANUAL-262 Rev.IR Market – Hog & Poultry