Hog Slat Inc. Newton Grove, NC USA January 2021 REV A9 9 Pit Scraper Systems WIRING INSTRUCTIOINS - FIGURE 5 7. (Figure 5) illustrates field wiring installation of the HS588-24VDC Auto Pit Scraper Control. REFERENCE DRAWING HS588-24VDC-3 8. External limit switches (Limit #1 and Limit #2) wired “Normally Closed”. Switch part# EL1187 spring finger heavy duty IP68 rated limit switch or equivalent should be used. 9. When connecting wire from equipment to terminal clamp , remove no more than ¼”[6.35mm] of insulation from end of wire. Be sure there are no stray wire strands before inserting wire into terminal strip. Insert wire into terminal ¼” [6.35mm] and tighten terminal strip set screw. If screw terminal barrier strip is used, it is recommended to install insulated fork terminal on each wire and insert underneath screw terminal.
RkJQdWJsaXNoZXIy MTA3MzU=