Hog Slat Inc. Newton Grove, NC USA March 2018 3 Heating System LB White Heaters The Hog Slat HSXF120-24 Universal Transformer mounts the same as the LB White (LB09615) OEM transformer. Wiring will require the following steps: Step 1. Remove all Quick Disconnects from old Transformer; white, black, yellow & green. Please note; there may be two white and two black leads on some units connected to the same transformer terminals with “piggyback terminals.” (See Fig.1 and Fig. 2) Fig. 1 Fig. 2 Step 2. Remove old transformer from heater (save two mounting screws). Strip all 4 (or 6) old leads (black(2), white(2), yellow & green) approximately ½”. (See Fig. 3) Step 3. Assemble new Transformer using saved mounting screws. (See Fig. 4) Fig. 3 Fig. 4 Step 4. Using appropriate size wire nuts, attach black transformer lead to stripped black lead(s). Repeat for white lead(s) and either yellow lead. Attach red lead from new transformer to remaining stripped green lead. (See Fig. 5) Tuck leads in cabinet and close door. Fig. 5