Hog Slat Inc. Newton Grove, NC USA AUG 2025 REV A4 27 Ventilation System 22C: ACTIVATE/DE-ACTIVATE CURVE: Press icon to activate the curves. Icon will change to red color indicating the button has changed operation to allow you to De-activate the curves. 22D: CURVE STATUS: Once the curve has been activated, the CURVE STATUS will indicate the current day, temperature and fan speed % currently active from the curve. If the curve needs to begin on a different day than the first day entry, press the block displaying the DAY# in the Curve Status area. This will launch a key pad titled DAY# 1 Entry. Simply select the day number you want the curve to begin and press ENTER. Curve will then start on that day and temperature will update to show value at that point on the curve. 22E: PAUSE/RESUME: When the Temperature curve is activated, a PAUSE button will appear. This will allow user to temporarily pause the curve function. Controller will revert to manual set-point. This feature is helpful when repair is needed and adjustment of set point is required during repair. When curve is paused, a pause icon will 22E 22F