Hog Slat Inc. Newton Grove, NC USA July 2024 REV A5 9 Ventilation System the system. If a load is too high and blows the fuse regularly, use an external contactor with appropriate rating for the load. NO user serviceable parts inside. Refer to the wiring diagram for connections. To gain access to interior of controller, slide latch located on right side upward to release front cover. Route all wiring through bottom of the controller enclosure through provided knockout profiles for ½” trade size fittings. DO NOT LEAVE OPEN HOLE(S) IN ENCLOSURE. USE ONLY NON-RIGID CONDUIT WITH LIQUID TIGHT CONNECTION. Loosen the (2) screws and remove lower cover to access area for installation of conduit fittings etc… This area provides additional room for wires. Pre-formed hole locations located on bottom of controller enclosure. HIGH VOLTAGE Pre-formed knockout profiles located on bottom of controller.