Hog Slat Feed Bin Installation Operation English Manual

Hog Slat Inc. Newton Grove, NC USA Sept. 2021 10 Feed Bins 12’ Diameter Feed Bins # of Rings Slab Thickness (T) Concrete Volume Wire Mesh Area Qty of Square 1-5 15" [381 mm] 9.1 Cu. Yards [6.93 Cu. Meters] 196 Sq. Ft. [18.21 Sq. Meters] 8 Square 6-7 16" [406 mm] 9.7 Cu. Yards [7.40 Cu. Meters] 196 Sq. Ft. [18.21 Sq. Meters] 8 Round 1-5 15" [381 mm] 7.1 Cu. Yards [5.45 Cu. Meters] 155 Sq. Ft. [14.40 Sq. Meters] 8 Round 6-7 16" [406 mm] 7.6 Cu. Yards [5.81 Cu. Meters] 155 Sq. Ft. [14.40 Sq. Meters] 8 1. Foundation recommendations are based on 3500 lbs / ft2 allowable soil bearing capacity. 2. Foundation recommendations are based on a minimum compressive strength of 3000 PSI at 28 days. 3. The foundation site must be well drained and free of vegetation and debris. 4. The foundation should be level within 1/4" overall and within +/-1/8” in any 10 foot length along the anchor bolt circle. 5. Material estimates do not include allowance for shrinkage and waste. 6. These layouts are recommendations for Hog Slat tanks only. Consult Hog Slat engineering for special tank foundations. 6” maximum above Grade 6” maximum above Grade Square Foundation Round Foundation