Hog Slat Inc. Newton Grove, NC USA Sept. 2021 9 Feed Bins 9’ Diameter Feed Bins # of Rings Slab Thickness (T) Concrete Volume Wire Mesh Area Qty of Square 1-7 13" [330 mm] 4.9 Cu. Yards [4.85 Cu. Meters] 125 Sq. Ft. [11.61 Sq. Meters] 6 Round 1-7 13" [330 mm] 3.8 Cu. Yards [2.91 Cu. Meters] 100 Sq. Ft. [9.29 Sq. Meters] 6 1. Foundation recommendations are based on 3500 lbs / ft2 allowable soil bearing capacity. 2. Foundation recommendations are based on a minimum compressive strength of 3000 PSI at 28 days. 3. The foundation site must be well drained and free of vegetation and debris. 4. The foundation should be level within 1/4" overall and within +/-1/8” in any 10 foot length along the anchor bolt circle. 5. Material estimates do not include allowance for shrinkage and waste. 6. These layouts are recommendations for Hog Slat tanks only. Consult Hog Slat engineering for special tank foundations. Square Foundation Round Foundation 6” maximum above Grade 6” maximum above Grade