Hog Slat - Plastic Flooring System Instruction Manual

Hog Slat Inc. Newton Grove, NC USA May 2024 4 Plastic Flooring System End Caps for Fiberglass Beams It is absolutely necessary to always use the HSFBM135-EC end caps (Figure 1 & 2) on the fiberglass beams. This is to avoid damage of the supporting beam from rough concrete. Tap end caps on carefully with rubber hammer until it fits snugly. NOTE: Failure to use HSFBM135-EC end caps will void warranty. Figure 1 Figure 2 Calculation Tool – Supporting Beams HSFBM135-XXX Fiberglass reinforced support beams Application Nursery Farrowing Animal Loading Density 32 lbs./ft2 50 lbs./ft2 Max Span of HSFBM135-XXX 120 inches (3.05 meters) 96 inches (2.44 Meters) **For spans greater than the max span, use support pedestal (reference parts list, page 11) to support beam at spans equal to or less than that of the max span listed above.** PVC Maximum Height 20”