Use VANTEK SLAT PATCH at a preconditioned temperature of 71 ± 5° F (22 ± 3° C). Use 5.25 – 5.75 (2.5 – 2.7L) pints of water or mixing liquids per 50lb (27.2kg) bag. Small Batch: Mix 1-part liquids with 4 to 5 parts mortar. Mixing must be achieved mechanically using a slow speed, 1/2 inch (12.7mm) drill and mixing paddle. Mix while slowly adding the powder to the water or mixing liquids. Mix smaller batches for small repairs or repairs in tight areas. Mix up to 4 minutes to a uniform lump-free consistency. Avoid over mixing which could entrap air. Note: In Hot Weather, add 1 pouch of SLOW SET Additive per gallon (3.8L) of mixing liquids to extend the working time 15-20 minutes. Just dissolve the SLOW SET into the mixing liquids. USING WITH POLYMER V or ACRYLIC RESIN as ADMIX AND BONDING AGENT General Repairs: Mix 1 part POLYMER V or ACRYLIC RESIN with 3 parts water for ADMIX & PRIMING. Thin and Performance Overlays: Increase the concentration of polymer or resin to enhance the properties. Typically 1-gallon of POLYMER V or ACRYLIC RESIN is needed for 3 bags MORTAR for General Repairs. Vantek warrants for a period of one (1) year that its products will be free of manufacturing defects and will be in conformity with published specifications when handled, stored, mixed, and applied in accordance with recommendations of Vantek. If any product fails to meet this warranty, the liability of Vantek will be limited to replacement of any non-conforming material if notice of such nonconformity is given to Vantek within (1) one year of delivery of materials. Vantek may in its discretion refund the price received by Vantek in lieu of replacing the material. No customer, distributor, or representative of Vantek is authorized to change or modify the published specifications of this warranty in any way. No one is authorized to make oral warranties on behalf of Vantek. In order to obtain replacement or refund the customer must provide written notice containing full details of the non-conformity. Vantek reserves the right to inspect the non-conforming material prior to replacement. EXCEPT FOR THE EXPRESSED WARRANTY STATED ABOVE, THERE ARE NO OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WITHOUT LIMITATION, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR PURPOSE. VANTEK'S OBLIGATION SHALL NOT EXTEND BEYOND THE OBLIGATIONS EXPRESSLY UNDERTAKEN ABOVE AND VANTEK SHALL HAVE NO LIABILITY OR RESPONSIBILITY TO THE PURCHASER OR ANY THIRD PARTY FOR ANY LOSS, COST, EXPENSE, DAMAGE OR LIABILITY, WHETHER DIRECT OR INDIRECT, OR FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. Limited Warranty Safety Considerations • Use adequate ventilation. • Use of NIOSH/MSHA approved dust vapor respirator, safety goggles and protective gloves are recommended. First Aid • EYE CONTACT: Flush immediately with water for at least 15 minutes. Contact physician immediately. • RESPIRATORY CONTACT: Remove person to fresh air. If the discomfort persists, breathing difficulty occurs, or if swallowed seek medical attention. • SKIN CONTACT: Remove any contaminated clothing. Wash skin thoroughly with soap and water. If irritation persists, seek medical attention. KEEP CONTAINER TIGHTLY CLOSED – KEEP OUT OF REACH OF CHILDREN – NOT FOR INTERNAL CONSUMPTION – FOR INDUSTRIAL USE ONLY Surface Preparation (See ICRI guidelines) 1. Concrete must be sound and fully cured (28 days). 2. Saw cut the perimeter of the area being patched into a square with a minimum depth of 1/2" (12.5 mm) for a uniform repair zone over a floor. 3. Remove all unsound concrete and roughen the surface to min. 1/4" (6.35mm) profile for overlayments. 4. Remove all laitance, oil, grease, curing compounds, and other contaminants that could prevent adequate bond. 5. If acid etching, follow guidelines. A visual etch should be present. 6. The concrete substrate should be saturated surface dry (SSD), without standing water, before application. Prime the substrate with a wet solution of mortar and water or resin/water mix to enhance the bond. 7. Apply the mixed material onto the prepared saturated surface dry (SSD) substrate by trowel or screed. Ensure proper consolidation of the mortar and compaction around reinforcing steel. Minimum application thickness is 1/2” (12.5 mm) based on a 3/8” (9.5 mm) diameter max. coarse aggregate. Straight mortar may be applied at 1/4” (6.35 mm) thickness. Finish the completed repair, as required, taking care not to overwork the surface. 8. For repairs over 2” (50.8 mm) deep the material should be extended 50% by weight with clean, SSD, 3/8” (9.5 mm) pea gravel or rock conforming to ASTM C 33. 9. For enhanced bond and to minimize absorption, use POLYMER V or ACRYLIC RESIN mixed with water as a primer. 10. Top Coating with 440LV EPOXY or V-GARD: During initial set apply a light broom or textured finish to the VANTEK SLAT PATCH surface. A light broadcast of 440LV Broadcast Aggregate can also be uniformly spread on the wet mortar surface. Apply the coating or overlay after full mortar cure. Do not use POLYMER V or ACRYLIC RESIN as admix if using epoxy over the top. Reinforcing Steel Remove all oxidation and scale from the exposed reinforcing steel. Prime the exposed steel with RUST STOPPER or VANTEK 803 Epoxy Gel for optimum seal. Application Mixing VANTEK Concrete Restoration and Protection Slat Patch Repair Mortar VANTEK CRP | NEWTON GROVE, NC | VANTEKCRP.COM APRIL 2024 Clean tools and equipment with clean water immediately after use. Cured material must be removed mechanically. CLEAN UP Caution
RkJQdWJsaXNoZXIy MTA3MzU=