Windstorm WS-54P Series Galvanized Butterfly Fan Installation Manual

Hog Slat Inc. Newton Grove, NC USA December 2022 10 Wind Storm Fans 8. Assemble cone. This step requires (2) installers. Begin by placing one cone panel on the ground with the end with connection slots slightly elevated. Insert the connection tabs into the connection slots and rotate to parallel. Continue for all 4 panels. (IF ONLY 2 PERFORATED PANELS ARE PRESENT THEY MUST BE INSTALLED OPOSING ONE ANTHOER AND INSTALLED ON THE FAN IN THE 3 OCLOCK AND 9 OCLOCK POSITION) 9. Connect cone panels to form round shape. This step requires (2) installers. Stand the cone upright with the larger diameter on the ground and force the cone to bend to allow the final connection tabs to insert into the remaining connection slots. Secure round connections with 5/16” serrated bolts (605095) and serrated nuts (606240) leaving the slots closet to the larger diameter and the 3rd row of holes closest to the small diameter open at this time. 10. Install Weather stripping around the outer ring of the butterfly. Cut holes or break stripping to allow for mounting bolts to pass. ! TO ENSURE PROPER DRAINAGE ENSURE GAP IN WEATHERSTRIPPING OF AT LEAST 1 INCH AT BOTTOM OF BUTTERFLY AFTER INSTALL! 11. Insert butterfly assembly into cone leaving the doors to open toward large end. The 4 mounting holes in the butterfly should align with the 3rd row of holes in the cone assembly. Insert 5/16” X 1 1/2” Hex head bolts through the butterfly and cone with the bolt head on the inside of the butterfly. The image below is provided for clarity.