Windstorm WS-F52B2 Series Galvanized Butterfly Fan Installation Manual

Hog Slat Inc. Newton Grove, NC USA December 2022 1 Wind Storm Fans WS-F52B2A Fan 52” Galv BFY 1.5HP 1725RPM 230V 60 Hz Only WS-F52B2A3 Fan 52” Galv BFY 2.0HP 1725RPM 230/460V 3P 60 Hz Only WS-F52B2A-V Fan 52” Galv BFY 2.0HP 1725RPM 230V VFD 1/3P Drive Inc WS-F52B2A-NM Fan 52” Galv BFY No Motor 60 Hz Only (Non GrowerSelect Product) (Includes Spanish Version - Incluye versión en español)

Hog Slat Inc. Newton Grove, NC USA December 2022 2 Wind Storm Fans Table of Contents GrowerSELECT General Page.................................................................................................................................3 Safety .........................................................................................................................................................................4 Warning Labels .......................................................................................................................................................4 Installation ...............................................................................................................................................................5 Operation Safety .....................................................................................................................................................5 Maintenance Safety ................................................................................................................................................5 Installation.................................................................................................................................................................6 Framing ...................................................................................................................................................................6 Assembly.................................................................................................................................................................7 Wiring...................................................................................................................................................................... 19 VFD Initial Set Up. .................................................................................................................................................. 23 Pre-Operation Assessment .................................................................................................................................. 26 Operation................................................................................................................................................................ 26 Maintenance ........................................................................................................................................................... 27 Troubleshooting .................................................................................................................................................... 29 Exploded Diagrams/Replacement Parts ............................................................................................................. 30 Hog Slat Limited Warranty.................................................................................................................................... 31 Página general de GrowerSELECT.......................................................................................................................... 35 Seguridad ............................................................................................................................................................... 36 Etiquetas de advertencia ..................................................................................................................................... 36 Instalación ........................................................................................................................................................... 37 Seguridad de la operación ................................................................................................................................... 37 Seguridad del mantenimiento ............................................................................................................................. 37 Instalación .............................................................................................................................................................. 38 Enmarcado ........................................................................................................................................................... 38 Ensamblaje .......................................................................................................................................................... 39 Alambrado .............................................................................................................................................................. 51 Configuración Inicial VFD. ................................................................................................................................... 55 Evaluación previa a la operación ........................................................................................................................ 58 Operación ................................................................................................................................................................ 58 Diagramas ampliados/Piezas de reemplazo ......................................................................................................... 62 Garantía limitada de Hog Slat ................................................................................................................................ 63

Hog Slat Inc. Newton Grove, NC USA December 2022 3 Wind Storm Fans GrowerSELECT General Page General Installation Notes: Make sure that power is disconnected from system prior to servicing. Installation of this equipment and related OEM equipment should be in accordance with these instructions, OEM’s installation instructions and local codes (if applicable). Failure to follow specified instructions may cause damage to equipment and/or personal injury or death. Take special note of any Warnings or Safety Decals on the equipment and in manuals. Always wear protective clothing and any applicable Personal Protective Equipment (Safety Glasses and/or Ear Plugs) when working with the equipment. Discarded materials, equipment and boxes should be recycled in accordance with local and national codes. Safety Instructions: Read all safety messages in this manual and on equipment safety decals. Follow recommended precautions and safe operating practices. Ground all electrical equipment for safety. Ground all non-current carrying metal parts to guard against electrical shock. Always keep safety decals in good condition and replace missing or damaged decals.

Hog Slat Inc. Newton Grove, NC USA December 2022 4 Wind Storm Fans Safety Warning Labels Warning Decals have been placed on the equipment to warn of potentially dangerous situations. Care should be taken to keep this information intact and easy to read at all times. Replace missing or damaged safety signs. Safety–Alert Symbol This is a safety–alert symbol. When you see this symbol on your equipment, be alert to the potential for personal injury. GrowerSelect equipment is designed to be installed and operated as safely as possible...however, hazards do exist. Safety decals should be read and understood thoroughly by individuals within the local area of the fan. Safety decals should be visible from both the front and back of the fan. Should a decal be missing or damaged, please contact Hog Slat Inc. for a free replacement: Hog Slat Inc. 206 Fayetteville St. Newton Grove, NC 28366 Toll Free: 800-949-4647 Local: 910-594-0219 The below safety decal should be represented and visible on both the front and back sides of the fan. This label is identified by the HSLABEL-080 part number in the lower right corner. WARNING – FLYING OBJECTS AND ROTATING PARTS Ensure fan guards are in place during operation. Securely tighten propeller to shaft to avoid slipping. Disconnect power supply for inspection or service when guards are removed and personnel are exposed to propeller. WARNING – HIGH VOLTAGE Disconnect electrical power before inspecting or servicing equipment unless maintenance instructions specifically states otherwise. Ground all electrical equipment for safety. All electrical wiring must be done by a qualified electrician in accordance with local and national electrical codes. Ground all non-current carrying metal parts to guard against electrical shock. With the exception of motor overload protection, electrical disconnects and over current protection are not supplied with the equipment.

Hog Slat Inc. Newton Grove, NC USA December 2022 5 Wind Storm Fans Installation Prior to any installation product should be inspected for any damage caused during shipping. Any damage found should be documented and communicated to liable parties. Operation Safety When fan is in operation no attempt should be made to service or interact with parts from the fan. Any attempt to interact with fan parts while the fan is operating could result in injury. Inlet and exit guards and or shutters are in place to help prevent foreign objects from entering inside the outer perimeter of the housing. If maintenance to the fan is required, interrupt the source of power to the motor and allow propeller to come to a complete stop before moving forward with any efforts to service. Maintenance Safety Wind Storm Fans are designed and built with operator safety in mind. Some safeguards must be disassembled or removed for the parts to be serviced or replaced. As this fan does have moving parts and is supplied with electrical power, steps must be taken to ensure safety around these presented hazards. READ THESE INSTRUCTIONS BEFORE SERVICE OR PART REPLACEMENT 1. Read and understand the operating manual before trying to install or operate Wind Storm Fans. 2. Power supply should be turned OFF and LOCKED OUT for service to motor and electrical components. Use CAUTION in checking voltage or other procedures requiring power to be ON. 3. DO NOT attempt to bypass any safety features or devices to operate the fan. 4. Keep fan clean of all debris that may collect the motor, prop, and any bearings, belts, or pulleys. 5. Use CAUTION is working around all moving parts of the fan. Fan guards or shutters must be in place before fan can be safely started and operational.

Hog Slat Inc. Newton Grove, NC USA December 2022 6 Wind Storm Fans Installation Framing The rough in opening for the fan is an exact measurement that accounts for the heads of fasteners and openings for fan. Ensure there is proper clearance for installation or rough opening may require larger measurements. Fan Model Rough Opening (Width x Height) 52” Butterfly Exhaust Fan 56 1/2” X 56 1/2” (143.5 cm x 143.5 cm) FAN SPACING Fans have a minimum spacing of 8” to avoid interference of cones. Fans may be spaced 3.5” if cone guards are modified (Minimum spacing will cause cones to be deformed)

Hog Slat Inc. Newton Grove, NC USA December 2022 7 Wind Storm Fans Assembly IT IS HIGHLY RECOMMENDED THAT ASSEMBLY AND INSTALLATION BE PERFORMED BY A MINIMUM OF 2 PEOPLE. 1. Remove packaging from fan and cone if applicable. • Locate hardware kit(s) and supplied literature and store for later use. • Ensure not to damage the fan or components during this step. ! FAN MUST NEVER REST ON PROP, SAWHORSES SHOULD BE USED FOR ANY STEP PRIOR TO MOUNTING ! 2. Hardware Bag Number 1 Should be used for this step Remove fan from crate and support so prop does not carry any load. Remove 2 screws attaching the top panel to the venturi. Lift the top panel until the flange on the top panel is flush with the venturi Secure with screws from Hardware Bag Number 1 beginning in the center and working outward. Repeat for the left, right, and bottom panels. Finally fasten the corners of the top and bottom panels to the right and left panels.

Hog Slat Inc. Newton Grove, NC USA December 2022 8 Wind Storm Fans 3. Hardware Bag Number 10 should be used for this step. Insert black plugs into the 4 panels where the original fasteners were attached. 4. Hardware Bag Number 2 should be used for this step. Partially insert the fan assembly into the framed opening. Insert the interior retaining tabs into the top and bottom slots. Ensure orientation is correct, motor plate should be located above the prop. Finish inserting fan into framed opening.

Hog Slat Inc. Newton Grove, NC USA December 2022 9 Wind Storm Fans 5. Hardware Bag Number 3 should be used for this step. Secure all 4 corners with supplied lag screws. Secure Top and Bottom center holes with supplied lag screws. Secure left and right center hole with retaining tab and washers. Place 2 washers between the housing and retaining tab then secure with lag screw. (If desired previously installed retaining tabs can be secured with a ¼” x 1-3/4” NOT PROVIDED)

Hog Slat Inc. Newton Grove, NC USA December 2022 10 Wind Storm Fans 6. Hardware Bag Number 4 should be used for this step. Rotate motor mounting plate to allow mounting pattern lines up with mounting pattern of the uprights. Secure with carriage bolts and lock nuts. 7. Hardware Bag Number 5 should be used for this step. Place motor onto motor plate with drive sheave oriented towards the prop. Loosely secure with carriage bolts, washers, and lock nuts. Push motor to the right as far as possible then completely tighten all fasteners.

Hog Slat Inc. Newton Grove, NC USA December 2022 11 Wind Storm Fans 8. Install Belt from Hardware Bag 11 by placing belt around tension arm and drive sheave, then rotate large pulley so the belt rotates onto the assembly. Check for proper tension, the second indicator mark on the belt tensioner is the desired operating tension. If belt lacks tension remove appropriate number of links and reinstall. ! BELT HAS AN ORIENTATION. THE CORRECT DIRECTION OF ROTATION IS INDICATED ON THE EXTERIOR FACE OF THE BELT WITH AN ARROW ! ! ENSURE ALL PULLEYS AND DRIVE COMPONENTS ARE PROPERLY ALIGNED TO ALLOW THE BELTS TO OPERATE ON THE SAME PLANE ! 9. Hardware Kit Number 6 should be used for this step.

Hog Slat Inc. Newton Grove, NC USA December 2022 12 Wind Storm Fans Assemble cone panels by placing tabs into slots until the flat is formed. Panels should be assembled so the half-moon drain tabs face installer and the slots are oriented to the left when installer is on side closest to drain tabs. Stand the assembly up (longer edge down) and lock together the final connection. Ensure tabs are completely bottomed out into slots then secure all panels with supplied fasteners by installing on the CENTER hole pattern. 10. Remove butterfly from packaging, ensure outside circumference is free of dirt, oil, or debris. Apply adhesive weather stripping to entire surface between all mounting holes. Finally remove adhesive backing.

Hog Slat Inc. Newton Grove, NC USA December 2022 13 Wind Storm Fans 11. Hardware Kit Number 8 should be used for this step. Insert butterfly into cone allowing the door to open towards the ground. Pull butterfly until 4 mounting holes align with slots on cone. Be careful to keep installed weather stripping in place during installation. Insert hex bolts from inside the butterfly protruding through the cone (Holes in the butterfly are threaded to help with assembly) 12. Hardware Kit Number 7 should be used for this step. Mount all 4 cone support brackets with fasteners as shown.

Hog Slat Inc. Newton Grove, NC USA December 2022 14 Wind Storm Fans 13. Determine orientation of butterfly and Insert stainless steel cable through the top hole in the cone. Secure with cable clamp. Pull the cable to the exit of the cone. 14. Attach cone assembly to the fan using the 4 cone mounting brackets with the butterfly oriented correctly. Use fender washers and lock nuts to loosely secure. Prior to final tightening from the inside of the house pull the butterfly as far into the cone (towards the prop) as possible then completely tighten fasteners. This is done to minimize light leaking around the butterfly.

Hog Slat Inc. Newton Grove, NC USA December 2022 15 Wind Storm Fans 15. Hardware kit number 9 should be used for this step. Attach cone exit guard to the cone using supplied fasteners. Wrap the cable around the bottom exit mounting bolt and tighten to secure cable. 16. Return to the inside of the fan and push drain tab down at the base of the butterfly to allow water to drain out. FAILURE TO MANIPULATE DRAIN TAB MAY LEAD TO A DECREASE IN THE USABLE LIFE OF THE PRODUCT !

Hog Slat Inc. Newton Grove, NC USA December 2022 16 Wind Storm Fans 17. From inside the house attach the butterfly bracket and springs (Hardware Bag 11) to the butterfly frame and doors as shown. 18. Assemble the inlet guard using zip ties from Hardware Bag 11 as shown. Mount inlet guard to fan inlet.

Hog Slat Inc. Newton Grove, NC USA December 2022 17 Wind Storm Fans 19. Finally mount inlet guard to fan by hooking top and bottom to retainer tabs and secure by rotating the locking tabs installed during step 5.

Hog Slat Inc. Newton Grove, NC USA December 2022 18 Wind Storm Fans

Hog Slat Inc. Newton Grove, NC USA December 2022 19 Wind Storm Fans Wiring To access motor, turn shutter retainer clips so shutter can be removed. Again, make sure that power is disconnected from system prior to servicing. Always ensure proper prop rotation after install or motor replacement. During operation air should be directed from inside the building to the outside. ALWAYS FOLLOW MOTOR WIRING DIAGRAM PROVIDED ON MOTOR! ELECTRICAL SHOCK HAZARD! • Motor replacement and the associated wiring changes should only be made by qualified and properly trained individuals. • Failure to follow the above warning can cause improper equipment function, premature failure of equipment or electrical shock, leading to property damage or personal injury. Single Phase (230 Volt Wiring) Three Phase (230/460 Wiring) -note rotation, if change is needed swap any leg (L1, L2, or L3).

Hog Slat Inc. Newton Grove, NC USA December 2022 20 Wind Storm Fans If you have purchased a product with a VFD Motor please see below! The following motors DO NOT contain internal thermal protection. They are intended to be used in conjunction with a variable frequency drive (Listed in table below). If any of the motors listed below are used in an application where they are not directly controlled by a variable frequency drive, then INSTALLATION/VALIDATION OF EXTERNAL THERMAL PROTECTION IS REQUIRED! EXTERNAL THERMAL PROTECTION SHOULD BE SIZED APPROPRIATELY Please reference NEC 430.31/430.32/430.40 for additional information regarding overload protection sizing. Motor Drive HS9308-VFD HSFI-1001 HS9306A-VFD HSFI-1001 HS9309-VFD HSFI-1001 HS9314-VFD HSFI-1002 HS9378-VFD HSFI-1002 NOTE: Please be aware that when determining wire and or breaker size and layout that fans with phase conversions (Single to Three Phase) should be sized according to the AMP draw of Drive and not the motor. Examples are shown below. Wire size should be appropriate to accommodate Drive’s input rated Amperage. Fan Model Number input Rated Amps AS-14EDDLP-V 8.8A AS-18EDDLP-V 8.8A AS-24EDDLP-V 8.8A AS-36EDDLPA-V 8.8A AS-54XEBDLP-V 13.3A AS-57EBDBP-V 13.3A AS-57EBDBPG-V 13.3A AS-54EDDLP-ID 20.0A WS-F52B2A-V 13.3A WS-54SBDLA-V 13.3A WS-54PBDBG-V 13.3A

Hog Slat Inc. Newton Grove, NC USA December 2022 21 Wind Storm Fans .

Hog Slat Inc. Newton Grove, NC USA December 2022 22 Wind Storm Fans

Hog Slat Inc. Newton Grove, NC USA December 2022 23 Wind Storm Fans VFD Initial Set Up. The following settings should be input to the drive initially. The start source, standard reference, and minimum frequency setting should be adjusted following minimum ventilation testing. In order to adjust the settings, provide power to the drive and depress the blue M button to access the set point menu. Example is provided below. To access/change settings depress blue M button, using the up and down arrows scroll until desired setting is on the display screen, Depress the blue M button to select the setting, using the up and down arrow keys input desired value. Once desired value is displayed depress the blue M butting again to save the setting. Use up and down arrows to advance to next setting. Setting 60Hz (208-240V) Supply 50Hz (208-240V) Supply P100 Start Control Source 0 0 P101 Standard Reference Source 0 0 P102 Minimum Frequency 30 30 P103 Maximum Frequency 60 50 P104 Acceleration Time 7 7 P105 Deceleration Time 7 7 P110 Start Method 5 5 P152 Scaling Frequency 60 50 P161 Speed at Max Frequency 60 50 P302 Motor Rated Voltage 230 220 P303 Motor Rated Current FLA from Motor @230V 60HZ FLA from Motor @ 220V 50Hz P304 Motor Rated Frequency 60 50 P305 Motor Rated Speed RPM from Motor @60Hz RPM from Motor @ 50Hz TO RESET DRIVE TO FACTORY SETTINGS CHANGE SETTING P199 TO 03 (For 60 Hz) OR 04 (For 50 Hz)

Hog Slat Inc. Newton Grove, NC USA December 2022 24 Wind Storm Fans Minimum Ventilation Testing The following steps should be taken BEFORE ANIAMALS ARE PLACED! If two drives are present both drives must be set up and tested simultaneously. Provide power to drive(s) and press the green Run button on both drive(s) Ensure fan(s) are operating and rotating correct direction. 30 Hz should be displayed on drive(s) Manually adjust the vents to the desired opening for minimum ventilation. Adjust fan(s) speed using the up and down arrows ensuring to adjust both units (if 2 drives are present) until the desired static pressure is reached. Note the setting! This is now the minimum frequency setting for minimum ventilation. Depress the Red stop button Following the same method from above adjust the following settings for all supply voltages and frequencies P100 Start Control Source Set to (1) Terminal Strip P101 Standard Reference Source Set to (1) 0-10VDC Terminal Strop P102 Minimum Frequency Set to frequency determined above in minimum ventilation testing If two drives are present ensure both drives are set up the same. Drive set up is now complete and is set to automatic mode (controlled via whole house controller) *The 0-10 Volt signal supplied from the whole house controller must be modified (scaled) appropriately based on minimum ventilation testing. 60Hz Example if 30 hz is determined to be the minimum setting the 0-10V signal should become 5-10V signal. 30Hz/60Hz = .5 .5 X 10V = 5V 50Hz Example if 30 Hz is determined to be the minimum setting the 0-10V signal should become 6-10V signal. 30Hz/50Hz=.6 .6 X 10V= 6V

Hog Slat Inc. Newton Grove, NC USA December 2022 25 Wind Storm Fans Back Up Thermostat Set Up The supplied Variable Frequency Drive is capable of accepting a backup signal to tell the drive to operate at a user defined speed if a condition is met. (Example a thermostat) The following steps and wiring diagram illustrate how to set this up. Connect back up signal device as shown below. Following the same method from above adjust the following settings P121 TB-13A Input Function Set to (3) Auto Reference: Preset 1 P125 Acceleration Time 2 Set to (7) Seconds P126 Deceleration Time 2 Set to (7) Seconds P131 Preset Speed #1 Set to desired override speed (60) Hz for full speed.

Hog Slat Inc. Newton Grove, NC USA December 2022 26 Wind Storm Fans General Installation Notes: Make sure that power is disconnected from system prior to servicing. Installation of this equipment and related OEM equipment should be in accordance with these instructions, OEM’s installation instructions and local codes (if applicable). Failure to follow specified instructions may cause damage to equipment and/or personal injury or death. Take special note of any Warnings or Safety Decals on the equipment and in manuals. Always wear protective clothing and any applicable Personal Protective Equipment (Safety Glasses and/or Ear Plugs) when working with the equipment. Discarded materials, equipment and boxes should be recycled in accordance with local and national codes. Safety Instructions: Read all safety messages in this manual and on equipment safety decals. Follow recommended precautions and safe operating practices. Ground all electrical equipment for safety. Ground all non-current carrying metal parts to guard against electrical shock. Pre-Operation Assessment Before beginning fan operation, please follow the below checklist to ensure that:  Fan power cord securely connected to a good power supply.  All safety labels are visible to personnel that will work in the area.  Exit wire guard and inlet shutter are in place and secured to the fan housing.  No foreign objects are protruding through the fan housing. Operation At all times during operation fan orifice should be free of debris. In the event any component of the fan is compromised discontinue use immediately and contact your local Hog Slat representative. During operation shutter doors should open completely and rotate a full 90 degrees. In the event shutter doors are not opening completely force door open 90 degrees. (Slight deformation of the corner of the shutter door lip is expected and will not affect the performance and or life of the shutter)

Hog Slat Inc. Newton Grove, NC USA December 2022 27 Wind Storm Fans Maintenance In order to begin any maintenance or service to the fan, power must be turned OFF and all moving parts must come to a complete STOP before accessing. All parts inside of the fan housing are accessed by removing the exit wire guard and inlet shutter. Once service is complete, clean excessive build-up from parts. Excessive dust and dirt on parts can cause vibration in the propeller and overheating of the motor. Before beginning operation again, ensure that all safeguards are back in place and all foreign objects are free from the area. DURING MAINTENANCE AND OPERATION THE FOLLING MUST BE MAINTAINED TO ENSURE PROPER PERFORMANCE AND TO EXTEND USABLE COMPONENT LIFE. • DRIVE COMPONENTS ALIGNMENT o Proper alignment of pulleys, tension arms, etc.. is required to avoid excessive belt and drive component wear. Failure to maintain correct alignment during maintenance will void warranty of drive components  A straight edge or laser alignment device should be utilized to check for alignment of drive components [! IMPORTANT ! If for any reason drive system components are removed/replaced or loosened; it is important to ensure that components are properly realigned to achieve proper performance and longevity ] • BELT TENSION AND DIRECTION (when applicable) o Proper belt tension and direction is critical to avoid excessive belt and drive component wear. Failure to maintain correct belt tension during operation or maintenance will void warranty of drive components.  Supplied belt tensioner should be used to ensure proper belt tension.  Correct operation occurs when the tension arm is operating at the second indicator mark  Correct belt direction (when applicable) can be determined by an indicator on the belt notating desired rotation direction

Hog Slat Inc. Newton Grove, NC USA December 2022 28 Wind Storm Fans • PROPER V GROOVE MAINTAINCE o Proper V groove dimensions are critical to maintaining performance and eliminating excessive belt wear. Failure to maintain proper V groove dimension will void warranty of drive components.  V belt gauges should be utilized to check for correct V groove dimensions.  Alternatively belts location on pulley can be used. Correct dimensions should allow belt to ride slightly above the outermost diameter of the pulleys, if belt rides below outermost diameter, pulley(s) should be changed.

Hog Slat Inc. Newton Grove, NC USA December 2022 29 Wind Storm Fans Please see below for direction regarding applying grease to pillow block bearings UCP20516G5 (Bearings shipped on Grower Select Fans) Grease Amount: (1) Stroke on most standard grease guns or 0.8 grams * Volume dispensed per stroke should be verified with grease gun manufacturer Grease Interval: Every 300 Hours of Operation Type of Grease: Lithium Based NLGI No.2 Note: ELECTRIC OR BATTERY POWERED GREASE GUNS SHOULD NOT BE USED AND MAY VOID WARRANTY! Troubleshooting Trouble Possible Cause(s) Corrective Action Excessive noise Worn motor bearing. Replace Damage to fan blade Replace prop Loose fasteners on motor or housing Tighten fasteners Excessive vibration Fan blade is out of balance due to dirt build-up. Clean entire unit Fan blade is out of balance due to damage Replace prop Insufficient airflow Intake or exhaust guards clogged with debris Clean entire unit Intake or exhaust blocked by foreign object Remove object from airflow path Fan won’t operate Open power supply circuit. Check wiring and reset circuit breaker Defective motor Reset motor, repair, or replace Motor overheats and nuisance trips Improper airflow due to clogged Inlet/Outlet Clean entire unit Motor or Fan prop has excessive debris build-up Clean entire unit

Hog Slat Inc. Newton Grove, NC USA December 2022 30 Wind Storm Fans Exploded Diagrams/Replacement Parts WS-F52B2A Item Part Number Description Fan 2 HS901-52 Shutter Butterfly 52" Galv Less Spring ALL 3 HS900-52G Prop 52" Windstorm Exhaust ALL 5 PAK4158 Pulley AK41-5/8 ALL 6 HS9019 Motor 1.5 HP 1725 RPM 50/60 Hz 1 PH 208-230V WS-F52B2A HS9378 Motor 2 HP 1725 RPM 208-230/460V 3 Ph 60 Hz TEAO WS-F52B2A3 HS9378-VFD Motor 2 HP 1725 RPM 208-230/460V 3 Ph 60 Hz TEAO VFD Compat WS-F52B2A-V 7 PAK941 Pulley AK94-1 ALL 8 HS903-3 Tensioner Rotary Assembly With Splash Guards ALL 9 UCP20516G5 Bearing 1" Pillow Block Standard 2 Set Screws ALL N/S HSAX57 Belt V 1/2'' X 59'' Cogged ALL N/S HS903-14 Spring Butterfly 52" Windstorm ALL N/S HSFI-1002 Inverter Frequency 2HP 240V 0-500Hz NEMA4X Outdoor WS-F52B2A-V For OSHA compliant guards, contact your local Hog Slat representative.

Hog Slat Inc. Newton Grove, NC USA December 2022 31 Wind Storm Fans Hog Slat Limited Warranty Hog Slat warrants products to be free from defects in material or workmanship for a period of twenty-four (24) months from the date of original purchase. Hog Slat will credit, repair, or replace, at its option any product deemed defective within this time period. Labor costs associated with the replacement or repair of the product are not covered by the Seller/Manufacturer. WS-F52B2A-NM Fan 52” Galv BFY No Motor 60 Hz Only (Non GrowerSelect Product) Conditions and Limitations 1. The product must be installed by and operated in accordance with the instructions published by the Seller/Manufacturer or Warranty will be void. 2. Warranty is void if all components are not original equipment supplied by the Seller/Manufacturer. 3. This product must be purchased from and installed by an authorized retailer/distributor or certified representative thereof or the Warranty will be void. 4. Malfunctions or failure resulting from misuse, abuse, negligence, alteration, accident, or lack of proper maintenance shall not be considered defects under the Warranty. 5. This Warranty applies only to components/systems for the care of poultry and livestock. Other applications in industry or commerce are not covered by this Warranty. 6. This Warranty applies only to the Original Purchaser of the product. The Seller/Manufacturer shall not be liable for any Consequential or Special Damage which any purchaser may suffer or claim to suffer as a result of any defect in the product. “Consequential” or “Special Damages” as used herein include, but are not limited to, lost or damaged products or goods, costs of transportation, lost sales, lost orders, lost income, increased overhead, labor and incidental costs and operational inefficiencies. THIS WARRANTY CONSTITUTES THE SELLER/MANUFACTURER’S ENTIRE AND SOLE WARRANTY AND THIS MANUFACTURER EXPRESSLY DISCLAIMS ANY AND ALL OTHER WARRANTIES, INCLUDING, BUT NOT LIMITED TO, EXPRESS AND IMPLIED WARRANTIES AS TO MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSES SOLD AND DESCRIPTION OR QUALITY OF THE PRODUCT FURNISHED HEREUNDER. Hog Slat Retailers/Distributors are not authorized to modify or extend the terms and conditions of this Warranty in any manner or to offer or grant any other warranties for GrowerSelect products in addition to those terms expressly stated above. An officer of Hog Slat must authorize any exceptions to this Warranty in writing. The Seller/Manufacturer reserves the right to change models and specifications at any time without notice or obligation to improve previous models.

Hog Slat Inc. Newton Grove, NC USA December 2022 32 Wind Storm Fans This equipment must be installed in accordance with all State and Local Codes and applicable Regulations which should be followed in all cases. Authorities having jurisdiction should be consulted before installations are made. Hog Slat, Inc. PO Box 300 Newton Grove, NC 28366 Phone: (910) 594-0219 Fax: (910) 594-1392 www.hogslat.com Copyright © 2016 by Hog Slat, Inc. Part Number: HSManual-090 Rev C5 HSART-427 Market: Poultry

Hog Slat Inc. Newton Grove, NC USA December 2022 33 Wind Storm Fans WS-F52B2A Ventilador 52” Galv BFY 1.5HP 1725RPM 230V 60 Hz Solamente WS-F52B2A3 Ventilador 52” Galv BFY 2.0HP 1725RPM 230/460V 3P 60 Hz Solamente WS-F52B2A-V Ventilador” Galv BFY 2.0HP 1725RPM 230/460 VFD 1/3P Incluye Unidad de Impulso WS-F52B2A-NM Ventilador 52” Galv BFY No Motor 60 Hz Solamente (Non GrowerSelect Product)

Hog Slat Inc. Newton Grove, NC USA December 2022 34 Wind Storm Fans Índice GrowerSELECT General Page.................................................................................................................................3 Safety .........................................................................................................................................................................4 Warning Labels .......................................................................................................................................................4 Installation ...............................................................................................................................................................5 Operation Safety .....................................................................................................................................................5 Maintenance Safety ................................................................................................................................................5 Installation.................................................................................................................................................................6 Framing ...................................................................................................................................................................6 Assembly.................................................................................................................................................................7 Wiring...................................................................................................................................................................... 19 VFD Initial Set Up. .................................................................................................................................................. 23 Pre-Operation Assessment .................................................................................................................................. 26 Operation................................................................................................................................................................ 26 Maintenance ........................................................................................................................................................... 27 Troubleshooting .................................................................................................................................................... 29 Exploded Diagrams/Replacement Parts ............................................................................................................. 30 Hog Slat Limited Warranty.................................................................................................................................... 31 Página general de GrowerSELECT.......................................................................................................................... 35 Seguridad ............................................................................................................................................................... 36 Etiquetas de advertencia ..................................................................................................................................... 36 Instalación ........................................................................................................................................................... 37 Seguridad de la operación ................................................................................................................................... 37 Seguridad del mantenimiento ............................................................................................................................. 37 Instalación .............................................................................................................................................................. 38 Enmarcado ........................................................................................................................................................... 38 Ensamblaje .......................................................................................................................................................... 39 Alambrado .............................................................................................................................................................. 51 Configuración Inicial VFD. ................................................................................................................................... 55 Evaluación previa a la operación ........................................................................................................................ 58 Operación ................................................................................................................................................................ 58 Diagramas ampliados/Piezas de reemplazo ......................................................................................................... 62 Garantía limitada de Hog Slat ................................................................................................................................ 63

Hog Slat Inc. Newton Grove, NC USA December 2022 35 Wind Storm Fans Página general de GrowerSELECT Notas generales de instalación: Asegúrese de que la energía esté desconectada del sistema antes de realizar el mantenimiento. La instalación de este equipo y del equipo relacionado del *FOE debe cumplir estas instrucciones, las instrucciones de instalación del FOE y los códigos locales (si corresponde). El incumplimiento de las instrucciones especificadas puede causar daños al equipo y daños personales o la muerte. Preste especial atención a las calcomanías de seguridad o advertencias en el equipo y en los manuales. Siempre use ropa de protección y cualquier equipo de protección personal aplicable (gafas de seguridad o tapones para los oídos) cuando trabaje con el equipo. Los materiales, equipos y cajas desechados deben reciclarse en conformidad con los códigos locales y nacionales. Instrucciones de seguridad: Lea todos los mensajes de seguridad en este manual y en las calcomanías de seguridad del equipo. Cumpla las precauciones recomendadas y las prácticas de operación segura. Conecte a tierra todos los equipos eléctricos por seguridad. Conecte a tierra todas las piezas metálicas no conductoras para evitar descargas eléctricas. Mantenga siempre las calcomanías de seguridad en buenas condiciones y reemplace las calcomanías dañadas o faltantes.

Hog Slat Inc. Newton Grove, NC USA December 2022 36 Wind Storm Fans Seguridad Etiquetas de advertencia Las calcomanías de advertencia se han colocado en el equipo para advertir de situaciones potencialmente peligrosas. Se debe procurar mantener esta información intacta y fácil de leer en todo momento. Vuelva a colocar las señales de seguridad dañadas o faltantes. Símbolo de alerta de seguridad Este es un símbolo de alerta de seguridad. Cuando vea este símbolo en su equipo, esté alerta ante la posibilidad de una lesión personal. El equipo GrowerSelect está diseñado para ser instalado y operado con la mayor seguridad posible, sin embargo, existen riesgos. Las personas que se encuentran dentro del área local del ventilador deben leer y entender perfectamente las calcomanías de seguridad. Las calcomanías de seguridad deben ser visibles desde la parte frontal y posterior del ventilador. En caso de que una calcomanía falte o se dañe, póngase en contacto con Hog Slat Inc. para obtener un reemplazo gratis: Hog Slat Inc. 206 Fayetteville St. Newton Grove, NC 28366 Teléfono gratuito: 800-949-4647 Local: 910-594-0219 La siguiente calcomanía de seguridad debe tener una representación adecuada y ser visible desde la parte frontal y posterior del ventilador. Esta etiqueta está identificada por el número de pieza HSLABEL-080 en la esquina inferior derecha. ADVERTENCIA – OBJETOS EN EL AIRE Y PIEZAS GIRATORIAS Asegúrese de que los protectores estén colocados durante el funcionamiento. Ajuste firmemente la hélice al eje para evitar el deslizamiento. Desconecte el suministro de energía para inspeccionar o reparar el equipo cuando las protecciones se retiren y el personal quede expuesto a la hélice. ADVERTENCIA – ALTO VOLTAJE Desconecte la energía eléctrica antes de inspeccionar o reparar el equipo a menos que las instrucciones de mantenimiento especifiquen lo contrario. Conecte a tierra todos los equipos eléctricos por seguridad. Todo el alambrado eléctrico debe ser realizado por un electricista calificado en conformidad con los códigos eléctricos locales y nacionales. Conecte a tierra todas las piezas metálicas no conductoras para evitar descargas eléctricas. A excepción de la protección de sobrecarga del motor, no se suministran desconexiones eléctricas y protección contra sobrecorriente con el equipo.

Hog Slat Inc. Newton Grove, NC USA December 2022 37 Wind Storm Fans Instalación Antes de cualquier instalación, el producto se debe inspeccionar por cualquier daño causado durante el envío. Cualquier daño encontrado debe documentarse y comunicarse a las partes responsables. Seguridad de la operación Cuando el ventilador está en funcionamiento, no se debe intentar reparar o interactuar con las piezas de este. Cualquier intento de interactuar con las piezas del ventilador mientras el ventilador está funcionando podría ocasionar una lesión. Los protectores de entrada y salida y las persianas ayudan a evitar que entren objetos extraños en el perímetro exterior de la caja de alojamiento. Si se debe realizar un mantenimiento del ventilador, corte la fuente de energía al motor y espere que la hélice se detenga por completo antes de seguir adelante con cualquier intento de reparación. Seguridad del mantenimiento Los ventiladores Wind Storm están diseñados y construidos teniendo en cuenta la seguridad del operador. Algunas protecciones se deben desmontar o retirar para reparar o reemplazar las piezas. Dado que este ventilador tiene piezas móviles y alimentación eléctrica, se deben tomar medidas para garantizar la seguridad en torno a estos riesgos. LEA ESTAS INSTRUCCIONES ANTES DE REALIZAR REPARACIONES O REEMPLAZAR PIEZAS 6. Lea y entienda el manual de funcionamiento antes de intentar instalar o hacer funcionar los ventiladores Wind Storm. 7. La fuente de energía debe estar APAGADA y BLOQUEADA para realizar reparaciones del motor y los componentes eléctricos. Tenga PRECAUCIÓN al verificar el voltaje u otros procedimientos que requieran que la energía esté ENCENDIDA. 8. NO intente evitar los dispositivos o las funciones de seguridad para hacer funcionar el ventilador. 9. Mantenga el ventilador libre de los desechos que pueda acumular el motor, la hélice y cualquier cojinete, correa o polea. 10. Tenga PRECAUCIÓN al trabajar alrededor de las piezas móviles del ventilador. Las protecciones o persianas del ventilador deben estar colocadas antes de que el ventilador pueda encenderse y ponerse en funcionamiento de manera segura.

Hog Slat Inc. Newton Grove, NC USA December 2022 38 Wind Storm Fans Instalación Enmarcado La abertura rústica para el ventilador es una medida exacta que considera las cabezas de los sujetadores y las aberturas para el ventilador. Asegúrese de que haya un espacio adecuado para la instalación o la abertura rústica podrá requerir medidas más grandes. Modelo del ventilador Abertura rústica (ancho x alto) Ventilador extractor mariposa de 52” 56 1/2” X 56 1/2” (143.5 cm x 143.5 cm) ESPACIADO DEL VENTILADOR Los ventiladores tienen un espaciado mínimo de 8” para evitar la interferencia de los conos. Pueden tener un espaciado de 3.5” si se modifican las protecciones del cono (Un espaciado mínimo provocará la deformación de los conos)

Hog Slat Inc. Newton Grove, NC USA December 2022 39 Wind Storm Fans Ensamblaje ES ALTAMENTE RECOMENDABLE QUE UN MÍNIMO DE 2 PERSONAS REALICEN EL ENSAMBLAJE Y LA INSTALACIÓN. 20. Retire el embalaje del ventilador y el cono si corresponde. • Localice el juego de herrajes y la documentación proporcionada y consérvelos para su uso posterior. • Asegúrese de no dañar el ventilador o los componentes durante este paso. ¡EL VENTILADOR NUNCA SE DEBE COLOCAR SOBRE LA HÉLICE, SE DEBEN USAR CABALLETES PARA CUALQUIER PASO PREVIO AL MONTAJE! 21. Para este paso debe usarse la bolsa de herrajes número 1 Retire el ventilador de la caja y ubíquelo de manera que la hélice no soporte ningún peso. Retire los 2 tornillos que sujetan el panel superior al venturi. Levante el panel superior hasta que la brida del panel superior esté al mismo nivel que el venturi. Fíjelo con los tornillos de la bolsa de herrajes número 1 comenzando en el centro y siguiendo hacia afuera. Repita el procedimiento para los paneles izquierdo, derecho e inferior. Finalmente, fije las esquinas de los paneles superior e inferior a los paneles derecho e izquierdo.

Hog Slat Inc. Newton Grove, NC USA December 2022 40 Wind Storm Fans 22. Para este paso debe usarse la bolsa de herrajes número 10. Introduzca los tapones negros en los 4 paneles donde se fijaron los sujetadores originales. 23. Para este paso debe usarse la bolsa de herrajes número 2. Introduzca parcialmente el ensamblaje del ventilador en la abertura enmarcada. Introduzca las lengüetas de retención interiores en las ranuras superior e inferior. Asegúrese de que la orientación sea correcta, la placa del motor debe estar ubicada por encima de la hélice. Termine de introducir el ventilador en la abertura enmarcada.

Hog Slat Inc. Newton Grove, NC USA December 2022 41 Wind Storm Fans 24. Para este paso debe usarse la bolsa de herrajes número 3. Fije las 4 esquinas con los tornillos proporcionados. Asegure los orificios centrales superior e inferior con los tornillos proporcionados. Asegure los orificios centrales izquierdo y derecho con la lengüeta de retención y las arandelas. Coloque las 2 arandelas entre la caja de alojamiento y la lengüeta de retención y luego asegure con un tornillo. (Si lo desea, las lengüetas de retención previamente instaladas se pueden asegurar con un tornillo de ¼” x 1-3/4” NO INCLUIDO)

Hog Slat Inc. Newton Grove, NC USA December 2022 42 Wind Storm Fans 25. Para este paso debe usarse la bolsa de herrajes número 4. Gire la placa de montaje del motor para permitir que el patrón de montaje se alinee con el patrón de montaje de los soportes. Asegure con pernos de carrocería y tuercas de fijación. 26. Para este paso debe usarse la bolsa de herrajes número 5. Coloque el motor sobre la placa del motor con la polea de mando orientada hacia la hélice. Coloque los pernos de carrocería, las arandelas y las tuercas de fijación sin ajustar. Empuje el motor tan a la derecha como sea posible, luego ajuste completamente los sujetadores.

Hog Slat Inc. Newton Grove, NC USA December 2022 43 Wind Storm Fans 27. Instale la correa de la bolsa de herrajes 11 colocando la correa alrededor del brazo tensor y la polea de mando, luego gire la polea grande de manera que la correa gire en el ensamblaje. Verifique que la tensión sea adecuada, la segunda marca indicadora en el tensor de la correa es la tensión de funcionamiento deseada. Si la correa tiene poca tensión, retire la cantidad adecuada de eslabones y vuelva a instalar. ! LA CORREA TIENE UNA ORIENTACIÓN. LA DIRECCIÓN CORRECTA DE ROTACIÓN ESTÁ INDICADA EN LA CARA EXTERIOR DE LA CORREA CON UNA FLECHA. ¡ASEGÚRESE DE QUE TODAS LAS POLEAS Y LOS COMPONENTES DE LA TRANSMISIÓN ESTÉN CORRECTAMENTE ALINEADOS PARA FUNCIONAR EN EL MISMO PLANO! 28. Para este paso debe usarse el juego de herrajes número 6.

Hog Slat Inc. Newton Grove, NC USA December 2022 44 Wind Storm Fans Ensamble los paneles del cono colocando las lengüetas en las ranuras hasta formar el plano. Los paneles deben ensamblarse de manera que las lengüetas de drenaje de media luna queden de frente al instalador y las ranuras queden orientadas a la izquierda cuando el instalador está en el lado más cercano a las lengüetas de drenaje. Coloque el ensamblaje en posición vertical (el borde más largo hacia abajo) y cierre la conexión final. Asegúrese de que las lengüetas estén bien colocadas en las ranuras, luego asegure los paneles con los sujetadores proporcionados instalándolos en el patrón de orificios CENTRALES. 29. Retire la mariposa del embalaje, asegúrese de que la circunferencia exterior esté libre suciedad, tierra o desechos. Coloque burletes en toda la superficie entre todos los orificios de montaje. Finalmente retire la capa adhesiva.

Hog Slat Inc. Newton Grove, NC USA December 2022 45 Wind Storm Fans 30. Para este paso debe usarse el juego de herrajes número 8. Introduzca la mariposa en el cono de manera que la puerta se abra hacia el suelo. Jale la mariposa hasta que los 4 orificios de montaje queden alineados con las ranuras del cono. Tenga cuidado de mantener los burletes colocados durante la instalación. Introduzca los pernos hexagonales desde el interior de la mariposa sobresaliendo a través del cono (Los orificios de la mariposa tienen rosca para ayudar con el ensamblaje) 31. Para este paso debe usarse el juego de herrajes número 7. Monte las 4 ménsulas de soporte del cono con los sujetadores tal como se muestra.

RkJQdWJsaXNoZXIy MTA3MzU=