Try this before you replace a failed jet pump on your cool cell system.
Try this before you replace a failed jet pump on your cool cell system.
We spoke with Hog Slat engineers, Tyler Marion and Tim King about the differences between using a jet or submersible pump to fill evaporative cooling systems. Here’s a quick synopsis of our discussion.
1) Jet pumps are more reliable because they can run dry for a period of time. For instance, if you discover during morning chores a leak occurring overnight had drained the system, a jet pump would still be working. A submersible pump that runs that long without water will need to be replaced.
2) Jet pump repairs are less costly. The impeller and motor are two individual components; a bad motor can be replaced separately. Submersible pumps are a single unit.
3) Jet pump repairs and service are easier. A jet pump system is all above ground…a submersible pump must be pulled from the sump for repairs. A drain plug on the GrowerSELECT jet pump allows easy access for service and winterizing.
4) The integrated trash basket on a jet pump protects the pump from debris.
5) Submersible pumps are designed to move waste water from underground applications; low volumes with high head pressures. Jet pumps are a better choice for evaporative cooling applications as they move larger volumes of water at reduced head pressures.
6) One of the advantages cited for using a sump/submersible pump system is the sump acts as an extra reservoir for the system. The bottom trough of an 80′ long system holds about 300 gallons of water. A typical sump only holds about 30 gallons; really an insignificant amount. The main purpose of a sump area is to provide a place where a submersible pump can run in water so it doesn’t burn up. (see 1.)
To order go to jet pump